Chapter 6 Cable Installation
physically located at the silk-screen identifier FE-C1/2 on the other RUIM1
board.
à
In case of being connected with a GB resource shelf, end B1 is located at the
silk-screen identifier FE1 on one RGUM1 board, while end B2 is located at
the silk-screen identifier FE2 on the RGUM2 board.
à
In case of being connected with other control shelf or switching shelf, end B1
is physically located at the silk-screen identifier FE2m-1 on the RUIM2, while
end B2 is physically located at the silk-screen identifier FE2m (m=1~5) on
the RUIM3.
l
When using 040502 version of CHUB rear board, there are 3 cases.
à
In case of being connected with a resource shelf at end B, end Bn (n=1...8)
for RCHB1 is physically located at the silk-screen identifier FE-C1/2 on one
RUIM1 board, while end Bn (n=1...8) for RCHB2 is physically located at the
silk-screen identifier FE-C1/2 on the other RUIM1 board.
à
In case of being connected with a GB resource shelf, end Bn (n=1...8) for
RCHB1 is located at the silk-screen identifier FE1 on one RGUM1 board,
while end Bn (n=1...8) for RCHB2 is located at the silk-screen identifier FE2
on the RGUM2 board.
à
In case of being connected with other control shelf or switching shelf, end Bn
(n=1...8) for RCHB1 is physically located at the silk-screen identifier FE2m-1
on the RUIM2, while end Bn (n=1...8) is physically located at the silk-screen
identifier FE2m (m=1~5) on the RUIM3.
– End of Steps –
6.7 Installing Interconnection Cable at User Plane
Context
It implements intra-system connection of resource shelf and switching shelf. Both ends of
fiber structure are LCP/PC connector without direction.
Steps
1.
For GB resource shelf, identify GUIM/GUIM2 and GLI/GLI4 configuration and
connection relation between GUIM/GUIM2 and GLI/GLI4.
For dual rack, GUIM/GUIM2 and GLI/GLI4 configuration is shown in
.
6-21