ZXG10 iBSC Hardware Installation Guide
l
Heat-shrinkable tube (black).
shows the structure of grounding cable.
Figure 7-37 Structure of Grounding Cable
1.
Grounding terminal (at
grounding clip side)
2.
Φ12 heat-shrinkable tube
3.
10mm
2
copper core cable
with 80cm length
4.
Grounding terminal (at
grounding busbar side)
If you want to make the grounding cable, you can do the following procedure:
1.
Strip the 13 mm outer sheath from two ends of the cable with copper core and put the
copper cable onto two Φ12 heat-shrinkable tubes.
2.
Press two ends of copper core cable for two terminals by using a hydraulic crimper,
handle the heat-shrinkable tube by using electric blower, enable it align the copper
core cable and terminal surface.
Note:
Keep the heat-shrinkable tube flat at two ends and closely contact the grounding
terminal and cable. If there is any damage on the heat-shrinkable tube, you shall
make it again.
7-30
SJ-20110531095035-004|2011-10-28 (R2.0)
ZTE Proprietary and Confidential
Summary of Contents for ZXG10 iBSC