background image

2

EASY DO’S & DON'T’S FOR INSTALLING A SUMP PUMP 

 

  1.   

DO

 read thoroughly all installation material provided with the pump. 

  2.   

DO

 inspect pump for any visible damage caused by shipping.  Contact dealer if pump appears to be damaged. 

  3.   

DO

 clean all debris from the sump.  Be sure that the pump will have a hard, flat surface beneath it.  

DO

 

NOT

 install on sand, gravel or 

dirt.

  4.   

DO

 be sure that the sump is large enough to allow proper clearance for the level control switch(es) to operate properly. 

  5.   

DO Always Disconnect Pump From Power Source Before Handling

   DO 

always connect to a separately protected and properly grounded circuit.  

   DO

 

NOT

 ever cut, splice, or damage power cord.  

   DO

 

NOT

 carry or lift pump by its power cord.  

   DO

 

NOT

 use an extension cord with a sump pump. 

  6.   

DO

 install a metal check valve and an all metal union in the discharge line.  

   DO

 

NOT

 use a discharge pipe smaller than the pump discharge without first

    consulting pump manufacturer.
  7.   

DO

 

NOT

 use a sump pump as a trench or excavation pump, or for pumping sewage, gasoline, or other hazardous liquids.  

  8.   

DO

 test pump immediately after installation to be sure that the system is working properly. 

  9.   

DO

 cover sump with an adequate sump cover. 

 10.   

DO

 review all applicable local and national codes and verify that the installation conforms to each of them. 

 11. 

DO

 consult manufacturer for clarifications or questions.

 12. 

DO

 inspect and test system for proper operations at least every 3 months.

YOUR ASSURANCE 

OF QUALITY 

Manufacturer warrants, to the purchaser and subsequent owner during 

the warranty period, every new product to be free from defects in material 

and workmanship under normal use and service, when properly used 

and maintained, for a period of one year from date of purchase by the 

end user, or 18 months from date of original manufacture of the product, 

whichever comes first.  Parts that fail within the warranty period, one year 

from date of purchase by the end user, or 18 months from the date of 

original manufacture of the product, whichever comes first, that inspections 

determine to be defective in material or workmanship, will be repaired, 

replaced or remanufactured at Manufacturer's option, provided however, 

that by so doing we will not be obligated to replace an entire assembly, 

the entire mechanism or the complete unit.  No allowance will be made 

for shipping charges, damages, labor or other charges that may occur 

due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any 

material or product that has been disassembled without prior approval 

of Manufacturer, subjected to misuse, misapplication, neglect, alteration, 

accident or act of nature; that has not been installed, operated or main-

tained in accordance with Manufacturer's installation instructions; that 

has been exposed to outside substances including but not limited to the 

following:  sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon 

derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive 

substances, wash towels or feminine sanitary products, etc. in all pump-

ing applications.  The warranty set out in the paragraph above is in lieu 

of all other warranties expressed or implied; and we do not authorize 

any representative or other person to assume for us any other liability in 

connection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  

40211  USA,  Attention:  Customer  Service  Department  to  obtain  any 

needed repair or replacement of part(s) or additional information pertain-

ing to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH 

OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED 

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF 

MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE 

EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied war-

ranty, so the above limitation may not apply to you. Some states do not 

allow the exclusion or limitation of incidental or consequential damages, 

so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other 

rights which vary from state to state.

LIMITED WARRANTY

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

Summary of Contents for Water Solutions 3098 Series

Page 1: ...l indicate if the power neutral and ground wires are correctly connected to your outlet If they are not call a qualified licensed electrician 5 ForAdded Safety Pumping and other equipment with a 3 prong grounded plug must be connected to a 3 prong grounded receptacle For added safety the receptacle may be protected with a ground fault circuit interrupter When a pump needs to be connected in a wate...

Page 2: ...ions determine to be defective in material or workmanship will be repaired replacedorremanufacturedatManufacturer soption providedhowever that by so doing we will not be obligated to replace an entire assembly the entire mechanism or the complete unit No allowance will be made for shipping charges damages labor or other charges that may occur due to product failure repair or replacement This warra...

Page 3: ...nstructions for other types of control usage FLOAT ROD ASSEMBLY INSTRUCTIONS AUTOMATIC ONLY OFF ON High Temperature On Off Float Positions High Temperature Float Rod Assembly 1 Slide two float stops 6 and small float 7 onto lower float rod 1 as shown If an extender kit P N 10 0656 is being used add additional lower floats provided with the kit 2 Slide lower float rod 1 through float rod guide 9 3 ...

Page 4: ...als could possibly deteriorate impeller and pump housing Check line Remove base and inspect D Pump will not shut off E Pump operates but delivers little or no water F Drop in head and or capacity after a period of use SERVICE CHECKLIST ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are wearing insulated protective sole...

Page 5: ...po de bombeo y otro equipo eléctrico deben conec tarse a un tomacorriente de 3 puntas con descarga a tierra con dispositivo interruptor interruptor accionado por corriente de pérdida a tierra 6 PARA SU PROTECCIÓN SIEMPRE DESCONECTE EL CORDÓN DE LA BOMBA Y EL CORDÓN DEL CONTROL DE LA FUENTE DE SUMINISTRO DE ENERGÍA ELÉCTRICA ANTES DE MANIPULAR Las bombas monofásicas se suministran con enchufes de 3...

Page 6: ...A RESPONSABILIDAD POR DAÑOS ESPECIALES EMERGENTES O INCIDENTALES O POR IN CUMPLIMIENTO DE LA GARANTÍA EXPRESA O IMPLÍCITA Y CUALQUIER GARANTÍAIMPLÍCITADEIDONEIDADPARAUNFINPARTICULARYDECOM ERCIALIZACIÓNSELIMITARÁALADURACIÓNDELAGARANTÍAEXPRESA Algunosestadosnopermitenlimitacionesenladuracióndeunagarantíaimplícita de forma que la limitación anterior podría no aplicar a usted Algunos estados no permit...

Page 7: ...cta y que los niveles On Off Activado Desactivado sean correctos también 13 PRECAUCIÓN No toque la unidad o la tubería con la unidad conectada a la fuente de suministro de energía eléctrica Haga los ajustes necesarios Instrucciones de montaje de la varilla de flotación Automática solamente Desactivado Posiciones del flotador On Off Activado Desactivado para alta temperatura Conjunto de la varilla ...

Page 8: ... estar abierto La altura de elevación de descarga excede la capacidad de la bomba Voltaje bajo o incorrecto Rotación incorrecta del motor Condensador defectuoso El agua de entrada contiene aire o hace que el aire entre en la bomba Aumento de fricción en la tubería línea o válvula de retención atascada Material abrasivo oproductos químicos adversos pueden deteriorar posiblemente el impulsor o la ca...

Page 9: ...nophasées sont équipées d un cordon avec une broche de mise à la terre pour protéger contre les électrocutions IL NE FAUT JAMAIS ENLEVER LABROCHE DE TERRE Il faut brancher la fiche à trois broches dansunepriseàtroisbrochesavecmiseàlaterre Silecircuitn estpaséquipé d une telle prise il faut en installer une en respectant les codes électriques nationaux et locaux 7 Risque d électrocution Ne pas enle...

Page 10: ...S ET TOUTE GARANTIE IMPLICITE D APPLICABILITÉ À UNE UTILISATION SPÉCIFIQUE OU DE COMMERCIALITÉ EST LIMITÉE À LA DURÉE DE LA GARANTIE EXPRESSE Certaines provinces ne permettent pas les limitations de la durée de la garantie implicite et il est possible que cette limitation ne s applique pas Certaines provinces ne permettent pas l exclusion ou la limitation des dégâts secondaires ou indirects et il ...

Page 11: ...ux et locaux 2 Installer un Unicheck combinaison raccord et clapet de sécurité de préférence juste au dessus du puits pour permettre la dépose facile de la pompe pour nettoyer ou la réparer N utiliser que des clapets de sécurité entièrement métalliques 3 Quand un Unicheck est installé percer un trou de 5 mm 3 16 dans le tuyau de refoulement au niveau du haut de la pompe REMARQUE Le trou doit aussi...

Page 12: ...lotteurcoincécontrelaparoidupuits interrupteurdé fectueux endommagé ou mal réglé E La pompe fonctionne mais son débit est faible Vérifierlecarterdecrépine letuyauderefoulementou siunclapetdesécuritéestinstallé sontrou ou non existant d éventdoitêtreouvert Lahauteurderefoulementestsupérieureàlacapacitédelapompe Mau vaisetension Mauvaisedirectionderotationdumoteur Condensateurdéfectueux Eaud aspirat...