7
AQUANOT
®
ACTIVE FLOAT SWITCH
FIGURE 6
SK3046
ACTIVE CONTROLLER FUNCTIONS
LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.
HIGH WATER
OPERATIONAL
LOW WATER
(OPTIONAL)
There are two buttons on the front of the controller.
-
Silence/Reset
• Can be pressed to silence current alarms for 24 hours.
•
Can be held for longer than 3 seconds to reset high water alarm. Reset will clear flashing light on unit.
• Other alarms must be cleared by a proper function of alarm component.
-
Self Test
•
Will run the pump when the low water light is green (float up or jumper installed) to determine if amp draw of pump is in range. If low water float is
used, unit will pump water to determine proper pump operation of check valve and discharge piping.
•
If low water float is down due to lack of water, controller will determine if pump is connected during self test, but will not run the pump due to lack
of water.
• Battery testing:
° Unit constantly monitors battery to determine if battery is connected and at proper voltage.
°
The battery is load-tested after every use of the pump.
•
Controller is factory programmed to self-test the pump every 24 hours for 10 seconds.
•
Holding the self-test button for 10 seconds will start the 24-hour timer for self-testing.
Solid Green
Flashing Yellow
Flashing Red
Fast-flashing Red
System Ready
Ready
--
--
--
AC power
--
--
No AC power
--
Battery
--
Charging
Disconnected or fault
--
DC pump
--
Pump running
Pump fault
--
Low water
--
Pit low on water
Float fault
Pump running continuously
Operational switch
--
System cycling/cycled
Float fault
--
High water switch
--
Float fault
High water condition
The LED light will display information about the controller.
Z CONTROL
®
GATEWAY
Once your Aquanot
®
Active 508 battery backup sump pump system is fully operational, the Z Control
®
Gateway device can be installed. The Gateway will allow your
Active Controller to communicate with the Z Control
®
Cloud. Once properly configured, alarms can be sent to users’ computers or mobile devices. Authorized users
of Z Control
®
Enabled devices can log into their Cloud account to silence alarms and test the equipment. A constant internet connection is required. The Gateway
may be connected to the home’s router with either an Ethernet cable or WiFi. The Gateway's connection to the Active Controller is by wire only.
For details please refer to FM2901, the Z Control
®
Gateway Installation Instructions.