2

LIMITED WARRANTY

MAINTENANCE

TROUBLESHOOTING INFORMATION

Manufacturer warrants, to the purchaser and subsequent owner during the warranty 

period, every new product to be free from defects in material and workmanship 

under normal use and service, when properly used and maintained, for a period of 

five years from date of purchase by the end user.  Zoeller batteries have a 3 year 

warranty. Parts that fail within the warranty period, that inspections determine to be 

defective in material or workmanship, will be repaired, replaced or remanufactured 

at Manufacturer's option, provided however, that by so doing we will not be obligated 

to replace an entire assembly, the entire mechanism or the complete unit.  No 

allowance will be made for shipping charges, damages, labor or other charges 

that may occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any 

material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or uncontrollable 

act of nature; that has not been installed, operated or maintained in accordance 

with  Manufacturer's  installation  instructions;  that  has  been  exposed  to  outside 

substances including but not limited to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in 

all pumping applications.  The warranty set out in the paragraph above is in lieu of 

all other warranties expressed or implied; and we do not authorize any representative 

or other person to assume for us any other liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, 

Attention: 

Customer Support Department to obtain any needed repair or replacement of part(s) 

or additional information pertaining to our warranty.

MANUFACTURER  EXPRESSLY  DISCLAIMS  LIABILITY  FOR  SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 

OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS FOR 

A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED 

TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, so the 

above limitation may not apply to you. Some states do not allow the exclusion or 

limitation of incidental or consequential damages, so the above limitation or exclusion 

may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

1.  Inspect and test the system for proper operations at least every 3 months.*

 

(a)  Green power "on" indicator light should be on, indicating AC power is 

on.

 

(b)  Unplug the primary pump and the controller from the power supply.

 

(c)  Fill the sump with water to the “on” level for the DC pump. Allow the pump 

to run a few minutes.

 

(d)  The alarm will sound approximately 3 seconds after the pump 

starts to 

run.

 

(e)  Push the Silence/Reset button. The alarm will go off.

 

(f)  The pump will shut off after the water level is lowered and the float 

drops to the "off" position.

2.  Plug the controller and the primary pump into the wall 

outlet.

 

(a)   The primary pump will come on, lower the water to the 

normal operating 

level and shut off.

 

(b)   The battery light will flash yellow when charging. The charger is replacing 

the energy consumed during the test. The green light will come on after 

the charger has replaced the energy consumed during the test.

*Wet cell batteries should be checked every month.

1.  DC Pump won’t run.

 

(a)  Check for proper connections.

 

(b)  Check all wire terminal points. Clean if required.

 

(c)  Check for low battery. Service battery if required.

 

(d)  Check 30 amp fuse in line from battery to controller (see fig. 3). If fuse is 

blown, replace with 30 amp Littelfuse type 3AG, series 311.

2.  Pump runs but pumps very little or no water without AC power.

 

(a)  Check for low battery. Battery will recharge if green power “on” light indicates 

power has been restored and the float switch is in the off position.

 

(b)  If immediate usage is required, remove and replace dead battery with a 

full recharged battery.

 

(c)  Due to varying conditions the pump may continue to run on a low battery 

without sufficient power to remove water.  Pump will not stop running until 

battery is completely discharged (10.5-10.8 Volts).

 

(d) 

CAUTION

 Weak batteries can be recharged but may not store 

sufficient  energy  for  full  service. A  weak  recharged  battery    can  only 

be detected by reduced pumping time or by professional load testing 

equipment. If your emergency pump system is used frequently the battery 

should be checked by a qualified battery dealer.

3.  Pump runs but pumps very little or no water.

 

(a)  Verfiy pump is connected completely.

 

(b)  Check to make sure pump weep hole is clear and unit is not airlocked.

 

(c)  Make sure discharge piping is not blocked.

4.  Pump cycles too frequently.

 

(a)  Check positions of rubber stops on operational float rod.

 

(b)  Adjust upper rubber float stop as required. Recommended for standard 

installation.

5.  Float switch in “on” position. Pump won’t run.

 

(a)  Make sure low water float is in "on" position (or jumpered). 

 

(b)  Remove pump. Check for obstruction in pump preventing impeller from 

rotating.

6.  Pump runs, but pumps water intermittently.

 

(a)  Pump is air locking. Check flow of water incoming to sump. If water is 

entering the sump at a high velocity creating a turbulent condition, a mixture 

of air and water may cause a complete or partial air lock and reduce or 

stop the flow of water in the discharge pipe.

 

(b)  Baffle the incoming stream of water to reduce turbulence. Diverting water 

stream against wall of basin usually corrects an air lock problem.

7.  Water level stays high. DC Pump continues to run.

    (a)  Battery is low.

    (b)  If power has been restored and water in sump remains high check primary 

pump. Service if required.

     (c)  After several hours the battery will be restored to full charge.

8.  Alarm sounds during battery recharge cycle.

    (a)  To silence alarm if alarm will not reset, unplug the charger from 115 V 

wall outlet, then disconnect the black lead from charger on negative (-) 

battery post. Check battery. Replace if necessary. Reconnect and refer 

to Installation (step 12).

NOTE: The Z Control

®

 Cloud may provide additional information.

In those instances where damages are incurred as a result of an alleged pump failure, 

the Homeowner must retain possession of the pump for investigation purposes.

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

Summary of Contents for AqyaNot 508 Active

Page 1: ...and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115 V receptacle available Do not use primary pump circuit The location must be within 6 1 8 m of the control box and battery The power supply for your DC control system plugsdirectlyintothe115Voutlet DO NOTUSEANEXTENSIONCORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breake...

Page 2: ...Plug the controller and the primary pump into the wall outlet a The primary pump will come on lower the water to the normal operating level and shut off b The battery light will flash yellow when charging The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test Wet cell batteries should be checked e...

Page 3: ...8 Active controller 1 153477 9 Battery box asm box and cover 1 10 0764 10 Hardware pak charger switch mode 1 152864 11 Fitting asm clamp 508 service part 1 152969 12 Flapper asm service part 1 152970 SK3047 The DC emergency pump system requires a good quality 12 volt battery to obtain maximum pumping time during a power outage A deep cycle 12 volt 105 amp hour marine battery or larger is recommend...

Page 4: ...to ensure the hose clamp screws will not interfere with the float operation of the primary pump 8 Assemble the operation float assembly per Figure 6 Install float switches as seen in Figure 1 9 The low water switch terminals have a jumper wire installed on the unit so no low water switch is necessary If you would like to use a low water switch install the low water float switch with the off level ...

Page 5: ...W WYE CAN BE USED AS WELL DO NOT USE DWV FITTINGS IF YOU PREFER TO USE THE LOW WATER FLOAT THE SUPPLIED JUMPER CAN BE REMOVED AND THE LOW WATER FLOAT INSTALLED IN ITS PLACE BATTERY BOX CHARGER OUTLET AQUANOT ACTIVE CONTROLLER Z CONTROL GATEWAY FIGURE 2 OPERATIONAL FLOAT SWITCH HIGH WATER FLOAT SWITCH SHOWN FOR CLARITY 1 1 2 INLINE CHECK VALVE LOW WATER CUT OUT FLOAT SWITCH OPTIONAL 1 2 5 cm MIN IM...

Page 6: ...OAT SWITCH OPTIONAL 1 SCH 40 PVC PIPE PROVIDED BY OTHERS LOW WATER CUTOFF FLOAT SWITCH CLAMP CLAMP CLAMP FLOAT CLIP DC PUMP BATTERY BOX 12 VOLT DEEP CYCLE BATTERY AQUANOT ACTIVE CONTROLLER OPERATIONAL FLOAT SWITCH HIGH WATER FLOAT SWITCH OPTIONAL OPTIONAL ETHERNET CABLE Z CONTROL GATEWAY 1 5 PVC TEE SCH 40 1 5 INLINE CHECK VALVE 30 AMP FUSE OPTIONAL Copyright 2016 Zoeller Co All rights reserved ...

Page 7: ... test the pump every 24 hours for 10 seconds Holding the self test button for 10 seconds will start the 24 hour timer for self testing Solid Green Flashing Yellow Flashing Red Fast flashing Red System Ready Ready AC power No AC power Battery Charging Disconnected or fault DC pump Pump running Pump fault Low water Pit low on water Float fault Pump running continuously Operational switch System cycl...

Page 8: ...e done to prevent the alarm activation MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Your Peace of Mind is Our Top Priority visit our web site www zoeller com There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never becom...

Page 9: ...a descarga a tierra No use el circuito de la bomba primaria Su ubicación debe estar dentro de 1 8 m 6 de la caja de control y de la batería El suministro eléctrico de su sistema de control de CD se enchufa directamente en el receptáculo tomacorriente de 115 V NO USE UN CORDÓN ALARGADOR 2 Asegúresedequeelcircuitodesuministroeléctricode115Vestéequipado con fusibles o interruptores automáticos de cap...

Page 10: ...gando El cargadorestáreemplazandolaenergíaconsumidadurantelaprueba La luz verde se encenderá después de que el cargador haya reemplazado la energía consumida durante la prueba Las baterías húmedas deberían ser revisadas cada mes 1 La bomba CD no funciona a Verifique que las conexiones estén correctas b Verifique todas las puntas de los terminales de alambre Limpie si es necesario c Verifique si la...

Page 11: ...8 8 Controlador activo 1 153477 9 Conjunto de caja la batería caja y tapa 1 10 0764 10 Paquete de herrajes cargador modo de conmutación 1 152864 11 Conector conjunto y abrazadera 508 pieza de repuesto 1 152969 12 Conjunto de charnela pieza de repuesto 1 152970 SK3047 El sistema de bomba de emergencia de CD requiere una batería de 12 V de buena calidad para obtener el tiempo de bombeo máximo durant...

Page 12: ...y pegue con soldadura en frío cualquier tubería de descarga restante por encima del codo NOTA Compruebe el funcionamiento del flotador para garantizar que los tornillos de la abrazadera de la manguera no interfieran con el funcionamiento del flotador de la bomba principal 8 Monte los componentes del flotador de funcionamiento según se ve en la Figura 5 Instale interruptores de flotador como se ve ...

Page 13: ...DE AGUA EL PUENTE SUMINISTRADO PUEDE SER RETIRADO Y EL FLOTADOR DE NIVEL BAJO DE AGUA PUEDE INSTALARSE EN SU LUGAR INTERRUPTOR DE FLOTADOR DE CORTE POR NIVEL BAJO DE AGUA OPCIONAL IMPORTANTE EL NIVEL DE APAGADO DEBE CONFIGURARSE POR ENCIMA DE LA ENTRADA DE LA BOMBA PRINCIPAL INTERRUPTOR DE FLOTADOR DE NIVEL ALTO DE AGUA FIGURA 2 2 5 cm 1 pulg MIN IMPORTANTE EL NIVEL DE APAGADO DE LOS COMPONENTES D...

Page 14: ...CH 40 DE DN40 1 PULG PROPORCIONADO POR TERCEROS INTERRUPTOR DE FLOTADOR DE CORTE POR NIVEL BAJO DE AGUA OPCIONAL ABRAZADERA ABRAZADERA ABRAZADERA GRAPA DE FLOTADOR BOMBA DE CC CAJA DE BATERÍA BATERÍA DE CICLO PROFUNDO DE 12 VOLTIOS AQUANOT ACTIVE INTERRUPTOR DE FLOTADOR DE FUNCIONAMIENTO INTERRUPTOR DE FLOTADOR DE NIVEL ALTO DE AGUA OPCIONAL CABLE DE ETHERNET Z CONTROL GATEWAY T DE PVC SCH 40 DE D...

Page 15: ...iene programado de fábrica para realizar un autodiagnóstico de la bomba cada 24 horas durante 10 segundos El mantener presionado el botón de autodiagnóstico durante 10 segundos iniciará el temporizador de 24 horas para el autodiagnóstico Verde fijo Amarillo parpadeante Rojo parpadeante Rojo parpadeante rápido Sistema listo Listo Alimentación de CA Sin alimentación de CA Batería Cargando Desconecta...

Page 16: ...rma Su tranquilidad es nuestra mayor prioridad visite a nuestro sitio web www zoeller com CORREO A P O BOX 16347 Louisville KY 40256 0347 USA ENVÍOS A 3649 Cane Run Road Louisville KY 40211 1961 USA 1 502 778 2731 FAX 1 502 774 3624 Cada año se fabrican millones de baterías por lo que es imposible garantizar una calidad constante Una batería defectuosa nunca llegará a cargarse completamente y pued...

Page 17: ...nt les pompes automatiques en courant continu doivent être équipée d un interrupteur à flotteur à niveau variable L installateur doit vérifier que l interrupteur à flotteur ne s accroche pas à la pompe ni aux aspérités du puisard et qu il est fermement installé pour permettrelamisenemarcheetl arrêtdelapompe Ilestrecommandéd avoir un puisard d au moins 45 cm 18 de diamètre pour permettre l installa...

Page 18: ...yer si nécessaire d Vérifier si la batterie est déchargée Faire de l entretien sur la batterie selon le besoin 2 La pompe fonctionne mais pompe très peu ou pas d eau sans courant alternatif a Vérifier si la batterie est déchargée La batterie doit se charger quand le voyant vert de marche est allumé indiquant que le système est sous tension et que l interrupteur à flotteur est en position d arrêt b...

Page 19: ... de matériel chargeur technologie d interrupteur 1 152864 11 Raccord ASM et collier 508 pièces de rechange 1 152969 12 Battant ASM pièce de rechange 1 152970 SK3047 Le système de pompe de secours doit être équipé d une batterie de 12 V de bonne qualité pour obtenir le meilleur pompage possible en cas de panne de courant Il est recommandé d utiliser une batterie marine à décharge poussée de 12 V 10...

Page 20: ...iliser cette mesure afin de couper le tuyau d évacuation Fixer cette pièce au coude à l aide de colle à solvant Mesurer couper et coller au solvant tout autre tuyau d évacuation restant au dessus du coude REMARQUE Vérifier le fonctionnement du flotteur afin de s assurer que les vis du collier du flexible n interfèrent pas avec le fonctionnement du flotteur de la pompe principale 8 Assembler le flo...

Page 21: ...IRETOUR ALIGNÉ 3 8 CM 1 5 PO INTERRUPTEUR À FLOTTEUR POUR ARRÊT EN CAS DE NIVEAU D EAU FAIBLE EN OPTION IMPORTANT LE NIVEAU D ARRÊT DOIT ÊTRE DÉFINI AU DESSUS DE L ENTRÉE DE LA POMPE PRINCIPALE SI VOUS PRÉFÉREZ UTILISER LE FLOTTEUR DE NIVEAU D EAU FAIBLE LE CAVALIER FOURNI PEUT ÊTRE RETIRÉ ET LE FLOTTEUR INSTALLÉ À SA PLACE FIGURE 2 2 5 cm 1 po MIN IMPORTANT LE NIVEAU D ARRÊT DU FLOTTEUR DOIT ÊTRE...

Page 22: ...ON TUYAU PVC DN40 1 1 2 PO SCH 40 FOURNIS PAR D AUTRES INTERRUPTEUR À FLOTTEUR POUR ARRÊT EN CAS DE NIVEAU D EAU FAIBLE EN OPTION COLLIER COLLIER COLLIER ATTACHE DE FLOTTEUR POMPE À COURANT CONTINU BOÎTIER DE BATTERIE BATTERIE 12 V À DÉCHARGE PROFONDE AQUANOT ACTIVE CONTRÔLEUR INTERRUPTEUR À FLOTTEUR OPÉRATIONNEL INTERRUPTEUR À FLOTTEUR DE NIVEAU D EAU ÉLEVÉ EN OPTION CÂBLE ETHERNET Z CONTROL GATE...

Page 23: ... d effectuer des autoévaluations de la pompe toutes les 24 heures durant 10 secondes Maintenir le bouton d autoévaluation pendant 10 secondes pour démarrer la minuterie de 24 heures de l autoévaluation Vert fixe Jaune clignotant Rouge clignotant Rouge clignotant rapidement Système prêt Prêt Alimentation c a Pas d alimentation c a Batterie En charge Déconnectée ou défaillante Pompe à courant contin...

Page 24: ...priorité absolue Visitez notre site internet www zoeller com ADRESSE POSTALE P O BOX 16437 Louisville KY 40256 0347 USA ADRESSE PHYSIQUE 3649 Cane Run Road Louisville KY 40211 1961 USA TÉL 1 502 778 2731 FAX 1 502 774 3624 Chaque année des millions de batteries sont fabriquées et il est donc impossible de garantir une qualité constante Une batterie défectueuse ne va jamais charger entièrement et p...

Reviews: