background image

9

3. Use

3.1 User interface presentation

TRi

TRi Expert

Access the user menu 

or return

From the home screen: increase or reducti on in disinfectant  producti on.

On the user menu: navigati on in the menu opti ons and value changes when a choice is 

proposed.

Validate a selecti on 

or access a sub-menu

Start or stop 

disinfectant producti on

Acti vate super-chlorinati on for a total period of 24 hours (blue indicator on)

Blocks disinfectant producti on at 10% (blue indicator on)

FLOW

Red indicator showing the absence of fl ow

POWER

Blue indicator showing 

disinfectant producti on (fl ashes if an error message is displayed, see 

“5. Troubleshooti ng”)

SALT

SALTS

Orange indicator showing a water conducti vity problem (not enough salt, water too cold, etc.)

If  the  language  displayed  on  the  screen  when  the  chlorinator  is  fi rst  powered  is  not  appropriate,  see  “3.2.5 

Language Menu”.

3.1.1 “Boost” mode

In certain cases your pool may need higher than normal chlorinati on (stormy weather, high number of bathers, etc.). The 

“Boost” mode is used to quickly increase disinfectant

 levels.

• 

Press the 

 butt on: “BOOST” is displayed on the screen and 100% disinfectant producti on starts.

• 

When “Boost” mode is acti vated, the electrolyser operates at a 100% disinfectant producti on level for a total 

24 hours. The number of days will therefore depend on the fi ltrati on operati ng ti mes. The appliance’s operati ng 

ti mes (see “«3.2.2 Programming Menu (Timers)»” are temporarily ignored for the durati on of the Boost mode. 

• 

The “Boost” mode cannot be started or stopped in the following conditi ons:

 

-

if the chlorinator is stopped,

 

-

if the chlorinator is connected to an automati on system (the “Boost” mode is then driven from the automati on 

system user interface).

Summary of Contents for TRi Series

Page 1: ...H0493600 D 2018 01 More documents on www zodiac com Instructions for installation and use English Salt water chlorinator Translation of the original instructions in french EN...

Page 2: ...omatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pump l...

Page 3: ...ng 14 Before you do anything with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may res...

Page 4: ...5 g h Nominal output Amps 2 8 A 2 8 A 3 6 A 3 6 A 5 A 7 2 A Required salt level minimum 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 4 g L mini 3...

Page 5: ...in the season pH 7 2 7 4 Add pH or use automatic regulation Add pH or use automatic regulation Weekly Free chlorine mg L or ppm 0 5 2 Increase the appliance s disinfectant production or use the Boost...

Page 6: ...ttings to x the cell to the pipes For 63 mm pipes glue them directly to the screw on ttings use a glue suitable for plumbing applications compatible with ABS and PVC material For 50 mm pipes use glue...

Page 7: ...n ltering is stopped red Flow indicator on showing the absence of ow see 5 Troubleshooting 2 5 Electric connections 2 5 1 Connecting the power pack The chlorinator can be connected in several di erent...

Page 8: ...to reassemble the module see the module s installation and user manual 1 2 The chlorinator is compatible with several di erent types of electric shutter However certain systems may not be compatible I...

Page 9: ...ndy AquaLink et Polaris EOS Pentair Intellitouch A Terminal black wire yellow wire B Terminal yellow wire green wire 0V Terminal green wire black wire POS Terminal red wire red wire 3 Close the chlori...

Page 10: ...uage displayed on the screen when the chlorinator is rst powered is not appropriate see 3 2 5 Language Menu 3 1 1 Boost mode In certain cases your pool may need higher than normal chlorination stormy...

Page 11: ...ollowing conditions if the chlorinator is stopped if the chlorinator is connected to an automation system but is not connected to a roll on shutter Low mode is then driven from the automation system u...

Page 12: ...restart production if necessary Creating a Timer On the home screen press the button Use the and buttons to reach the PROGRAMMING line then press to display the programming settings menu Use the and b...

Page 13: ...nnection to an electric roll on shutter On the home screen press the button Use the and buttons to reach the EXTERNAL CONTROLLER line then press to display the di erent models Use the and buttons to s...

Page 14: ...lignment Re t the tightening ring reconnect the cell cable and re t the protective cover Open the isolation valves and restart the ltering and chlorinator If you do not use a commercially available cl...

Page 15: ...lci Replace the electrode Clean the cell PUMP FLOW CONTROLLER FAULT Flow indicator red and lit The messages are displayed alternatively every 3 minutes Failure of the ltering pump The lter and or the...

Page 16: ...erie BP 90023 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number...