5

2.2 Installing the power pack

• 

The control box must be installed in a dry and venti lated equipment room protected against frost, with no pool main-

tenance products stored nearby.

• 

The control box must be installed a minimum of 3.5m from the surrounding edge of the pool. Any additi onal local instal-

lati on codes in the installati on country must also be adhered to.

• 

It must not be installed more than 1.8 metres from the cell (maximum cable length).

• 

If the pack is fi xed to a post, a waterti ght panel must be fi xed behind the control box (350x400 mm minimum).

• 

Fix the support solidly to the wall or the waterti ght panel, and place the power pack on it using the screws provided.

 2.3 Installing the cell

• 

The cell must be installed on the piping aft er the fi ltering, aft er any measurement sensors, and aft er eventual heati ng 

systems.

• 

Ideally the water should fl ow from the electric connecti ons towards the opposite side.

• 

Use the screw-on fi tti  ngs to fi x the cell to the pipes. 

• 

For Ø63 mm pipes, glue them directly to the screw-on fi tti  ngs (use a  glue suitable for plumbing applicati ons : compati ble 

with ABS and PVC material). For Ø50 mm pipes, use glue-on PVC adapters of the corresponding diameter (grey models; 

the white models are for 1 ½’’ UK pipes). 

• 

Connect the cell power supply cable following the wire colour codes (red, black and blue connectors) and then refi t the 

protecti ve cap.

•  The cell must be installed horizontally to ensure proper operati on and to avoid gas build up which can lead 

to equipment damage or serious injury.

•  The cell must always be the last element placed on the pool return pipe (see diagram).

•  It is always recommended to install the cell on a by-pass. This assembly is MANDATORY if the fl ow is in excess 

of 18 m³/hour to avoid load loss.

•  If you install the cell on a by-pass, it is recommended to fi t a check valve downstream from the cell instead of 

a manual valve, to avoid the risk of an improper setti  ng which could result in the incorrect fl ow water back 

into the cell.

•  The two red wires can be connected to one or the other red terminals on the electrode.

Summary of Contents for TRi Series

Page 1: ...H0493600 D 2018 01 More documents on www zodiac com Instructions for installation and use English Salt water chlorinator Translation of the original instructions in french EN...

Page 2: ...omatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pump l...

Page 3: ...ng 14 Before you do anything with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may res...

Page 4: ...5 g h Nominal output Amps 2 8 A 2 8 A 3 6 A 3 6 A 5 A 7 2 A Required salt level minimum 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 4 g L mini 3...

Page 5: ...in the season pH 7 2 7 4 Add pH or use automatic regulation Add pH or use automatic regulation Weekly Free chlorine mg L or ppm 0 5 2 Increase the appliance s disinfectant production or use the Boost...

Page 6: ...ttings to x the cell to the pipes For 63 mm pipes glue them directly to the screw on ttings use a glue suitable for plumbing applications compatible with ABS and PVC material For 50 mm pipes use glue...

Page 7: ...n ltering is stopped red Flow indicator on showing the absence of ow see 5 Troubleshooting 2 5 Electric connections 2 5 1 Connecting the power pack The chlorinator can be connected in several di erent...

Page 8: ...to reassemble the module see the module s installation and user manual 1 2 The chlorinator is compatible with several di erent types of electric shutter However certain systems may not be compatible I...

Page 9: ...ndy AquaLink et Polaris EOS Pentair Intellitouch A Terminal black wire yellow wire B Terminal yellow wire green wire 0V Terminal green wire black wire POS Terminal red wire red wire 3 Close the chlori...

Page 10: ...uage displayed on the screen when the chlorinator is rst powered is not appropriate see 3 2 5 Language Menu 3 1 1 Boost mode In certain cases your pool may need higher than normal chlorination stormy...

Page 11: ...ollowing conditions if the chlorinator is stopped if the chlorinator is connected to an automation system but is not connected to a roll on shutter Low mode is then driven from the automation system u...

Page 12: ...restart production if necessary Creating a Timer On the home screen press the button Use the and buttons to reach the PROGRAMMING line then press to display the programming settings menu Use the and b...

Page 13: ...nnection to an electric roll on shutter On the home screen press the button Use the and buttons to reach the EXTERNAL CONTROLLER line then press to display the di erent models Use the and buttons to s...

Page 14: ...lignment Re t the tightening ring reconnect the cell cable and re t the protective cover Open the isolation valves and restart the ltering and chlorinator If you do not use a commercially available cl...

Page 15: ...lci Replace the electrode Clean the cell PUMP FLOW CONTROLLER FAULT Flow indicator red and lit The messages are displayed alternatively every 3 minutes Failure of the ltering pump The lter and or the...