background image

6

EN

2.4 Installing the flow controller

The fl ow controller and its fi xture collar (Ø50 mm) must be installed on the piping close to the cell and upstream from it. 

Use the supplied threaded adapter and Tefl on tape to install the fl ow controller on its fi xture collar.

• 

Cell installed on a by-pass: the fl ow controller must be installed on the cell by-pass between the upstream isolati on 

valve and the cell itself.

• 

Cell installed in line: the fl ow controller must be installed just in front of the cell and aft er a possible valve.

• 

Tighten the fl ow controller using the ti ghtening nut only (ti ghten by hand!).

 

Tightening 

nut

• 

Failure to follow these instructi ons could lead to the destructi on of the cell ! (see “2.3 Installing the cell”). The 

manufacturer cannot be liable in this case.

• 

The fl ow detector has  a directi on  for installati on  (arrow indicated on  it  showing  the fl ow directi on  for the 

water). Make sure that is is correctly placed on its fi xture collar so that it stops the chlorinator producti on when 

fi ltering is stopped (red “Flow” indicator on showing the absence of fl ow, see “5. Troubleshooti ng”).

2.5 Electric connections

2.5.1 Connecti ng the power pack

The chlorinator can be connected in several diff erent ways. Be sure to comply with all applicable installati on codes and 

standards in the country of installati on.

• 

Preferred Connecti on: the appliance, including the provided fl ow controller, is connected to a permanent power supply, 

which is separate from the power supply controlling the fi ltrati on pump. The power supply for the appliance must 

be protected by a 30mA Residual Current Device (RCD) / Ground Fault Circuit Breaker, which is not provided with the 

appliance and must be sourced separately or provided by the installer.

• 

Possible connecti on: the appliance is connected directly with the pool fi ltrati on power circuit, thereby allowing power 

to be supplied to it only when the fi ltrati on pump is operati ng.

• 

When all connecti ons have been completed and all glued assemblies have dried, reconnect the mains power supply to 

power on the appliance.

Whichever connecti on is used, it is mandatory to programme the chlorinator operati ng ti mes (called “Timers”) 

(see “3.2.2 Programming Menu (Timers)”).

Summary of Contents for TRi Series

Page 1: ...H0493600 D 2018 01 More documents on www zodiac com Instructions for installation and use English Salt water chlorinator Translation of the original instructions in french EN...

Page 2: ...omatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pump l...

Page 3: ...ng 14 Before you do anything with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may res...

Page 4: ...5 g h Nominal output Amps 2 8 A 2 8 A 3 6 A 3 6 A 5 A 7 2 A Required salt level minimum 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 4 g L mini 3...

Page 5: ...in the season pH 7 2 7 4 Add pH or use automatic regulation Add pH or use automatic regulation Weekly Free chlorine mg L or ppm 0 5 2 Increase the appliance s disinfectant production or use the Boost...

Page 6: ...ttings to x the cell to the pipes For 63 mm pipes glue them directly to the screw on ttings use a glue suitable for plumbing applications compatible with ABS and PVC material For 50 mm pipes use glue...

Page 7: ...n ltering is stopped red Flow indicator on showing the absence of ow see 5 Troubleshooting 2 5 Electric connections 2 5 1 Connecting the power pack The chlorinator can be connected in several di erent...

Page 8: ...to reassemble the module see the module s installation and user manual 1 2 The chlorinator is compatible with several di erent types of electric shutter However certain systems may not be compatible I...

Page 9: ...ndy AquaLink et Polaris EOS Pentair Intellitouch A Terminal black wire yellow wire B Terminal yellow wire green wire 0V Terminal green wire black wire POS Terminal red wire red wire 3 Close the chlori...

Page 10: ...uage displayed on the screen when the chlorinator is rst powered is not appropriate see 3 2 5 Language Menu 3 1 1 Boost mode In certain cases your pool may need higher than normal chlorination stormy...

Page 11: ...ollowing conditions if the chlorinator is stopped if the chlorinator is connected to an automation system but is not connected to a roll on shutter Low mode is then driven from the automation system u...

Page 12: ...restart production if necessary Creating a Timer On the home screen press the button Use the and buttons to reach the PROGRAMMING line then press to display the programming settings menu Use the and b...

Page 13: ...nnection to an electric roll on shutter On the home screen press the button Use the and buttons to reach the EXTERNAL CONTROLLER line then press to display the di erent models Use the and buttons to s...

Page 14: ...lignment Re t the tightening ring reconnect the cell cable and re t the protective cover Open the isolation valves and restart the ltering and chlorinator If you do not use a commercially available cl...

Page 15: ...lci Replace the electrode Clean the cell PUMP FLOW CONTROLLER FAULT Flow indicator red and lit The messages are displayed alternatively every 3 minutes Failure of the ltering pump The lter and or the...

Page 16: ...erie BP 90023 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number...

Reviews: