11

 3.2.2 Programming Menu (Timers)

The chlorinator has two programmers to control 

disinfectant  producti on  ti mes.  These  are  called  “Timers  or 

“Operati ng ti me intervals”.

• 

“Timer” programming is used to defi ne the chlorinator operati ng ti mes within the fi ltering system opera-

ti on ti mes. The daily operati ng ti mes must be suffi  cient to correctly treat the water.

• 

A reminder of the calculati on rule (with a single speed fi ltrati on pump) : the ideal daily fi ltering ti me is 

obtained by dividing the required pool water temperature (measured in °C) by 2. Example: for water at 

28°C - 28/2 - 14 hours per day

•  The chlorinator is fi tt ed with a safety device to prevent disinfectant overproducti on. It switches off  the 

appliance aft er 30 hours of conti nuous disinfecti on (no «Timers(s)» memorised and fi ltering in conti nuous 
mode (manual mode)). Pressing the  

 butt on will restart producti on if necessary.

Creati ng a “Timer”

•  On the home screen press the 

 butt on.

• 

Use the 

 and 

 butt ons to reach the “PROGRAMMING” line, then press 

 to display the programming 

setti  ngs menu.

• 

Use the  

 and 

 butt ons to select the ti mer to set (“TIMER 1” or “TIMER 2”), then press  

.

• 

Use the  

 and 

 butt ons to set the starti ng ti me hour, then press 

 to memorise.

• 

Use the 

 and 

 butt ons to set the starti ng ti me minutes, then press  to 

 memorise.

• 

Use the 

 and 

 butt ons to set the stopping ti me hour, then press 

 to memorise.

• 

Use the 

 and 

 butt ons to set the stopping ti me minutes, then press 

 to memorise. The chlorinator  

returns to the “PROGRAMMING” menu automati cally.

• 

The “T” symbol is displayed in the upper right hand corner of the LCD display on the home screen if the programming 

is valid :

Deleti ng a “Timer”

•  On the home screen press the 

 butt on.

• 

Use the 

and 

butt ons to reach the “PROGRAMMING” line, then press 

 to display the programming 

setti  ngs menu.

• 

Use the  

and 

butt ons to reach “RAZ TIMERS”, then press 

. A message confi rming the deleti on will be 

shown on the screen.

Summary of Contents for TRi Series

Page 1: ...H0493600 D 2018 01 More documents on www zodiac com Instructions for installation and use English Salt water chlorinator Translation of the original instructions in french EN...

Page 2: ...omatically void the warranty Do not spray insecticide or any other chemical in ammable or non in ammable in the direction of the appliance as this may damage the body and cause a re Zodiac heat pump l...

Page 3: ...ng 14 Before you do anything with the device it is vital that you read this installation and user manual as well as the warnings and warranty booklet delivered with the device Failure to do so may res...

Page 4: ...5 g h Nominal output Amps 2 8 A 2 8 A 3 6 A 3 6 A 5 A 7 2 A Required salt level minimum 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 2 2 g L mini 1 6 g L 4 g L mini 3 3 g L 4 g L mini 3...

Page 5: ...in the season pH 7 2 7 4 Add pH or use automatic regulation Add pH or use automatic regulation Weekly Free chlorine mg L or ppm 0 5 2 Increase the appliance s disinfectant production or use the Boost...

Page 6: ...ttings to x the cell to the pipes For 63 mm pipes glue them directly to the screw on ttings use a glue suitable for plumbing applications compatible with ABS and PVC material For 50 mm pipes use glue...

Page 7: ...n ltering is stopped red Flow indicator on showing the absence of ow see 5 Troubleshooting 2 5 Electric connections 2 5 1 Connecting the power pack The chlorinator can be connected in several di erent...

Page 8: ...to reassemble the module see the module s installation and user manual 1 2 The chlorinator is compatible with several di erent types of electric shutter However certain systems may not be compatible I...

Page 9: ...ndy AquaLink et Polaris EOS Pentair Intellitouch A Terminal black wire yellow wire B Terminal yellow wire green wire 0V Terminal green wire black wire POS Terminal red wire red wire 3 Close the chlori...

Page 10: ...uage displayed on the screen when the chlorinator is rst powered is not appropriate see 3 2 5 Language Menu 3 1 1 Boost mode In certain cases your pool may need higher than normal chlorination stormy...

Page 11: ...ollowing conditions if the chlorinator is stopped if the chlorinator is connected to an automation system but is not connected to a roll on shutter Low mode is then driven from the automation system u...

Page 12: ...restart production if necessary Creating a Timer On the home screen press the button Use the and buttons to reach the PROGRAMMING line then press to display the programming settings menu Use the and b...

Page 13: ...nnection to an electric roll on shutter On the home screen press the button Use the and buttons to reach the EXTERNAL CONTROLLER line then press to display the di erent models Use the and buttons to s...

Page 14: ...lignment Re t the tightening ring reconnect the cell cable and re t the protective cover Open the isolation valves and restart the ltering and chlorinator If you do not use a commercially available cl...

Page 15: ...lci Replace the electrode Clean the cell PUMP FLOW CONTROLLER FAULT Flow indicator red and lit The messages are displayed alternatively every 3 minutes Failure of the ltering pump The lter and or the...

Page 16: ...erie BP 90023 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number...