MagnaPool™ | Installation Manual
8.10 Help Menu
The hydroxinator will automatically notify you of
any problems by displaying error messages. To
help with the understanding of these messages,
the controller has a troubleshooting assistance
menu which gives the meanings and the action to
take to solve the problem.
1. Press
.
2. Use
to select “Help Menu” then press .
3. Use
to select the error message
then press .
4. The display will automatically scroll through
a certain number of suggested solutions to
explain what to do. Once automatic scrolling
is complete, the hydroxinator automatically
returns to the “Troubleshooting” menu.
5. Press
to exit.
Section 9. Inspecting and Cleaning
The Electrode
In areas that experience calcium hardness the cell
electrode will benefit from cleaning.
1.
Switch off the filter pump and chlorine
generator, close necessary valves and unplug
the cell terminal cap.
2. Unscrew the retaining ring and remove the
electrode. If calcium buildup is present,
immerse the electrode in cell cleaning solution
without immersing the terminals.
3. We recommend using Zodiac Cell Cleaner to
clean the electrode. However, you can mix
your own by carefully adding one (1) part of
Hydrochloric (Muriatic) acid to ten (10) parts
water. Stronger solutions will shorten terminal
life.
4. Allow the cleaning solution to dissolve the
calcium deposits for about 10 minutes.
Dispose of the cleaning solution at an
approved Council Depot and never into storm
water or sewage drains.
5.
Rinse the electrode in clean water and re-fit
the electrode in the cell housing.
6. Replace the cell head and plug assembly.
7. Reset valves and switches.
8. Turn pump and controller on.
9.
Confirm chlorine output and settings on
the power pack. Timer programs will be
automatically retained.
Figure 25. Opening the Cell