Page 19
Page 18
MagnaPool™ | Installation Manual
<
-FILTER PUMP
-AUX/LIGHTS
-PROGRAMMING
-LOW MODE
-SLAVE MODE
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
-BACKWASH
-SINGLE SPEED
-VARIABLE SPEED
FILTER PUMP
<
PLUGD TO DEVICE?
-YES
-NO
SINGLE SPEED
8.1.2
Variable Speed Filter Pump
1. The following pump models are compatible:
FloPro™ VS, Flopro™ VS AUT
2.
Connect the filter pump to the controller at
the VSP RS485 connection point in the low
voltage raceway, see Table 5 and Figure 10 for
wiring details.
3. Ensure the RS485 wires are in the proper order.
LOW VOLTAGE
HIGH VOLTAGE
RED
BL
K
YE
L
GRN
On the Controller
RED BL
K
YE
L
GRN
On the Pump
4. Ensure the pump DIP switches are in the
correct position as follows:
1 = up
2 = up
3 = down
4 = down
5 = up
5. Press
.
6. Use
to select “Filter Pump”
then press .
7. Use
to select “Variable Speed”
then press .
8. The user interface will prompt “Variable Speed
Plgd to Device”. Use
to select “Yes”
then press .
9. Use
to select a speed then press .
10. Use
to adjust the RPM.
11. Once desired RPM is reached, press .
12. Press
to exit.
NOTE:
If multiple VSP timers have a time slot in common
: it is the higher RPM that will be operated.
<
-FILTER PUMP
-AUX/LIGHTS
-PROGRAMMING
-LOW MODE
-SLAVE MODE
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
-BACKWASH
-SINGLE SPEED
-VARIABLE SPEED
FILTER PUMP
<
PLUGD TO DEVICE?
-YES
-NO
VARIABLE SPEED
<
VARIABLE SPEED
-SPEEDS
-MIN/MAX
-PRIMING
-PROGRAMMING
<
VSP SPEEDS
-RPM 1 1000
-RPM 2 1500
-RPM 3 2000
-RPM 4 2850
-QUICK 3450
8.1.3
Quick Clean
Quick Clean is a backwash mode is used to quickly
start/stop the filter pump (single- or variable-speed
pump) in order to backwash the filter.
For variable speed pumps, the backwash RPM is
set under “Quick”.
1.
Select YES to activate filtration.
2.
Select NO to stop filtration.
For safety reasons, the hydroxination is stopped
during the backwash mode. To avoid emptying the
pool, the backwash mode automatically stops after
5 minutes. The variable speed pump RPM is by
default set at 3450 rpm (max speed). This can be
changed in the priming menu.
8.2
Aux/Lights
The hydroxinator is capable of controlling devices
in addition to the filter pump. The equipment
must be connected to the hydroxinator using the
appropriate auxiliary line:
Aux 1: for equipment connected to the high voltage
supply (230 V) (not applicable for Australia).
Aux 2: for equipment connected to the low voltage
supply (12/24 V).
The following functions are available in the
AUX/LIGHTS menu for auxiliaries 1 and 2:
● Turn the equipment on/off
● Program a timer (See section 8.7.6 for details)
For Australian products, in order to control
the light transformer, an additional switching
box is required. Please contact your local pool
care professional for this relay box, item code
WW000222.
1. Remove the lower cover from the housing.
2. Attach the 2 x core wires from the switch box
to the terminal bar marked ‘AUX 2’.
3. Replace the cover/s.
4. Plug the switch box into any
available 240V GPO.
5. Plug the light transformer directly into the
socket located in the switch box. This will now
control the light directly from the hydroxinator.