MagnaPool™ | Installation Manual
.
4. Use
to select value then press .
5. Press
to exit.
<
-PH SETUP
-ORP SETUP
-LOW MODE
MAIN MENU
<
-ORP SETPOINT
-ORP CALIBRATION
ORP SETUP
CHECK CYANURIC ACID
>30 PPM
TO AVOID ORP ISSUES
<
700 MV
RECOMMENDED
650-750 MV
ORP SETPOINT
• Default ORP setting is 700 mV.
• Acceptable range = 600 mV (min.) - 900 mV (max)
8.6
Prime and Test
the pH Dosing Pump
The dosing pump is deactivated during the first
8 hours of the device in order to prevent acid
exposure during installation. The pH dosing pump
can be directly activated directly in order to perform
a five-minute operating test.
WARNING
•
Hydrochloric acid is a hazardous chemical that
may cause burns, lesions, and irritations. Handle
with extreme care using protective equipment
(gloves, goggles, coveralls). Refer to the
substance SDS sheet for more information.
•
Always pour acid into water.
•
Dispose of the solution according to standard in
effect in the country of use.
1. Press
.
2. Use
to select “pH Setup” then press .
3. Use
to select “Test Dosage”
then press .
The acid pump will perform a five-minute
operating test.
4. Press
while “Start Test”
is selected to begin.
5. Press
while “Stop Test”
is selected to cancel.
6. Press
to exit.
<
-PH SETUP
-ORP SETUP
-LOW MODE
MAIN MENU
<
-TEST DOSAGE
PH SETUP
<
CONNECTIONS
START TEST
CHECK ACID
<
PROCEEDING
STOP TEST
ACID TEST
• Pump stops automatically upon completion of the
five-minute test.
• To prevent acid injection when it is not required: It
is possible to stop the pH dosing pump for 8 hours
through the “pH Setup” Menu.
8.7
Programming/Timers
The controller has two internal operating timers.
The timers are used to define the length of time
for the filter pump to operate, and the length of
time for the Hydroxinator to produce chlorine.
This offers the user the advantage of running their
variable speed pump longer at lower flow rates,
without having the hydroxinator producing the
whole time.
In order to complete the timer program, it is
necessary to enter and validate both ON and
OFF times. If no timer is set, the filtration and / or
hydroxination will run continuously
The filtration operating times must be sufficient to
correctly treat the water.
Example
- single speed pump:
In Season filtration time: 8-10 hours per day.
Off Season filtration time: 4-5 hours per day.
Example
- variable speed pump (when running at
lower speeds):
In Season filtration time: 12-14 hours per day
In Season HYDROX time: 8-10 hours per day
Off Season filtration time: 10-12 hours per day
Off Season HYDROX time: 4-5 hours per day
Once validated, The hydroxinator will adopt
the same timers as the filtration pump. The
hydroxination time must be equal or shorter than
the filtration time. The device will not accept a
hydroxination timer longer than or outside the
programmed filtration time.
8.7.1
Reset Timers
1. Press
.
2. Use
to select “Programming”
then press .
3. Use
to select “Reset Timers” then press .
The selected timers will be reset to 00:00.
8.7.2
Operation With an External Timer
In order for the controller to operate with an
external timer. All controller programs must be
cleared and the device must be on. After the
connection to the external timer is made, turn the
controller off then back on again.