Shanghai ZLAN Information Technology Co., Ltd Tel: +86-17321037177 http://www.zlmcu.com
50
Figure 39 TCP Devices Pair-connection Success Check
If the pair-connection in UDP mode, the configuration parameters are shown in
figure 40, and the corresponding parameters of the arrows must be one-to-one. In
UDP pair-connection the data will automatically be sent to the specified device as
long as the parameters are configured correctly without checking the connection
status.
Figure 40 UDP Device Pair-connection Configuration
Finally, it is necessary to remind that if the device is pair-connected, except the
Ethernet parameter configuration set as above, the serial port parameters also need
to be correctly set. It is mainly because the baud rate of the serial device server and
the baud rate of the user's device should be accordance. After this setting, user
devices can send data to each other through the serial port of two serial device
servers.
6. Device Debugging
6.1 Network Physical Connection
The serial device server can use cross wire or straight wire to connect 10M/100M switch
or directly connect to computer Ethernet port.