32
INSTALLATION AND OPERATING INSTRUCTIONS:
MFS02-S-KHC-IL
Device specific
Index
dec (hex)
Name
Format
(Offset)
Length
Access
1
Default
Value
Value / Range
Remark [Unit]
4367 (0x110F)
DD - Reset device diagnostics
parameters
UInt
8 Bit
wo
1 = Reset operating hours
2 = Reset power cycles
255 = Reset all device
diagnostics
parameters
DD - reset the device diagnostics
parameters
4368 (0x1110)
DD - Alert source
Record
2 Byte
rw
Set the alert source of the device diagnosis data
1 (0x01)
Operating hours alert source
Bit (8)
8 Bit
rw
0
0 = Total
1 = Since Last Reset
2 = Since Startup
2 (0x02)
Power cycles alert source
Bit (0)
8 Bit
rw
0
0 = Total
1 = Since Last Reset
4369 (0x1111)
DD - Alert limit
Record
8 Byte
rw
Set the limits of the device diagnosis alerts
1 (0x01)
Operating hours limit
Bit (32)
32 Bit
rw
876000
0...876000
[h]
2 (0x02)
Power cycles limit
Bit (0)
32 Bit
rw
1000000
4370 (0x1112)
DD - Alert flags
Record
1 Byte
ro
Get the device diagnosis alerts
1 (0x01)
Operating hours alert
Bit (1)
1 Bit
ro
true = Alert occurred
false = Alert did not occur
2 (0x02)
Power cycles alert
Bit (0)
1 Bit
ro
true = Alert occurred
false = Alert did not occur
4372 (0x1114)
Actuator travel [x10μm]
UInt
16 Bit
ro
[x10μm]
4374 (0x1116)
Total actuator travel [sum m]
UInt
32 Bit
rw
[m]
4375 (0x1117)
Average actuator velocity
[m/s]
Record
8 Byte
ro
1 (0x01)
Extend (positive direction)
Bit (32)
4 Byte
ro
Format = Float [m/s]
2 (0x02)
Retract (negative direction)
Bit (0)
4 Byte
ro
Format = Float [m/s]
4379 (0x111B)
Actuator travel time [ms]
Record
8 Byte
ro
1 (0x01)
Extend (positive direction)
Bit (32)
4 Byte
ro
Format = Float [m/s]
2 (0x02)
Retract (negative direction)
Bit (0)
4 Byte
ro
Format = Float [m/s]
4380 (0x111C)
Cycle time [ms]
Float
8 Byte
ro
[ms]
4381 (0x111D)
Dwell time [ms]
Record
4 Byte
ro
1 (0x01)
Start position
Bit (32)
4 Byte
ro
Format = Float [m/s]
2 (0x02)
Start position
Bit (0)
4 Byte
ro
Format = Float [m/s]
4382 (0x111E)
Cycle count [sum]
UInt
32 Bit
rw
4398 (0x112E)
Reset actuator diagnostics
parameters
UInt
8 Bit
ro
1 = Reset total actuator travel
2 = Reset actuator cycles
255 = Reset all actuator
diagnostics
parameters
DD - reset the device diagnostics
parameters
4399 (0x112F)
Actuator alert limits
Record
16 Byte
rw
Set the limits of the actuator alerts
1 (0x01)
Total actuator travel limit
Bit (96)
32 Bit
rw
100000
[m]
2 (0x02)
Min. cycle time limit
Bit (64)
4 Byte
rw
0
Format = Float
[ms]
3 (0x03)
Max. cycle time limit
Bit (32)
4 Byte
rw
86400000
Format = Float
[ms]
4 (0x04)
Cycle count limit
Bit (0)
32 Bit
rw
1000000
4400 (0x1130)
Actuator alerts
Record
2 Byte
ro
Get the actuator alerts
1 (0x01)
Total actuator travel alert
Bit (10)
1 Bit
ro
true = Alert occurred
false = Alert did not occur
2 (0x02)
Min. cycle time alert
Bit (9)
1 Bit
ro
true = Alert occurred
false = Alert did not occur
3 (0x03)
Max. cycle time alert
Bit (8)
1 Bit
ro
true = Alert occurred
false = Alert did not occur
4 (0x04)
Cycle count alert
Bit (7)
1 Bit
ro
true = Alert occurred
false = Alert did not occur
4602 (0x11FA)
Current field strength [mT]
Record
8 Byte
ro
Magnetic field strength of magnetic elements
1 (0x01)
Current1
Bit (32)
4 Byte
ro
Magnetic field strength of magnetic element 1. Format = Float [mT]
2 (0x02)
Current2
Bit (0)
4 Byte
ro
Magnetic field strength of magnetic element 2. Format = Float [mT]
4604 (0x11FC)
Peak field strength [mT]
Record
8 Byte
ro
1 (0x01)
Current1
Bit (32)
4 Byte
ro
Magnetic field strength of magnetic element 1. Format = Float [mT]
2 (0x02)
Current2
Bit (0)
4 Byte
ro
Magnetic field strength of magnetic element 2. Format = Float [mT]
4842 (0x12EA)
Alert settings
Record
8 Byte
rw
1 ro = read only, wo = write only, rw = read/write
2 COM values specify the bitrate (see IO-Link specification): COM1 (4,8 kbit/s), COM2 (38,4 kbit/s), COM3 (230,4 kbit/s)