Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
DDOC01932 / -
23
INSTALLATION AND OPERATING INSTRUCTIONS:
MFS02-S-KHC-IL
EN / 2023-07-07
11.5 Diagnostic functions via IO-Link
The following data are recorded by the product and can be output via the IO-Link interface:
•
Stroke (actuator travel)
•
Cycle time (Cycle time)
•
Dwell time of piston
•
in the start position (dwell time start position)
•
in the target position (dwell time stop position)
•
Travel time of piston
•
for extend (actuator travel time extend)
•
for retract (actuator travel time retract)
•
Average piston velocity
•
for extend (average actuator velocity extend)
•
for retract (average actuator velocity retract)
•
Current measured field strength
•
at sensor element 1 (current field strength sensor element 1)
•
at sensor element 2 (current field strength sensor element 2)
•
Maximum measured field strength
•
at sensor element 1 (peak field strength sensor element 1)
•
at sensor element 2 (peak field strength sensor element 2)
•
Number of cycles (cycle count)
•
Total amount of piston travel (total actuator travel)
•
Operating hours (operating hours count)
•
Power-on and power-off cycles (power cycles)
11.5.1 Stroke
The travel of the last stroke is output in mm via
Index 4372 (0x1114)/Actuator travel
.
11.5.2 Cycle time
The duration of the last cycle is output in ms via
Index 4380 (0x111C)/Cycle time
.
One cycle corresponds to two strokes, i.e. from the start position to the end position and from the end position back to the
start position. The start position is located on the side of the line, the end position on the side of the mounting screw.
The maximum cycle time and the minimum cycle time can be set via
Index 4399 (0x112F), Subindex 2 (0x02)/Min. cycle
time limit
and
Subindex 3 (0x03) Max. cycle time
. In addition, an alert can also be set for exceeding the limit values via
Index
4400 (0x1130), Subindex 2 (0x02)/Min. cycle time alert
and
Subindex 3 (0x03)/Max. cycle time alert
.
11.5.3 Dwell time at the start and end position
The dwell time at the start and/or end position can be output in ms via
Index 4382 (0x111D)/Dwell time, Subindex 1 (0x01)/
Start position
and
Subindex 2 (0x02)/Stop position
. The start position is located on the side of the line, the end position on
the side of the mounting screw.
11.5.4 Piston travel time for extend and retract
The duration of the last stroke for extend and/or retract can be output in ms via
Index 4379 (0x111B)/Actuator travel time
,
Subindex 1 (0x01)/Extend
and
Subindex 2 (0x02)/Retract
. The piston travels in the direction of the mounting screw for
extend and in the direction of the line for retract.