Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
DDOC01932 / -
15
INSTALLATION AND OPERATING INSTRUCTIONS:
MFS02-S-KHC-IL
EN / 2023-07-07
11.4.2 Resetting settings
•
The
Device Reset
command only deletes the volatile parameters. The command can be executed via
Index 2 (0x02)/
System Command, Value 128
.
Index
Name
Volatile/Non-volatile
4372 (0x1114)
Actuator travel
Volatile
4380 (0x111C)
Cycle time
Volatile
4381 (0x111D)
Dwell time
Volatile
4379 (0x111B)
Actuator travel time
Volatile
4375 (0x1117)
Average actuator velocity
Volatile
4602 (0x11FA)
Current field strength
Volatile
4604 (0x111FC)
Peak field strength
Volatile
4374 (0x1116)
Total actuator travel
Non-volatile
4382 (0x111E)
Cycle count
Non-volatile
Qint. 1-8 SP1 / SP2
Qint. 1-8 Configuration
Non-volatile
•
The
Restore Factory Settings
command resets all settings made back to the default settings. The command can be
executed via
Index 2 (0x02)/System Command, Value 130
. The following indices remain unchanged:
•
4356 (0x1104)/Operating hours
•
4357 (0x1105)/Power cycles, Subindex 1 (0x01)/Total
•
4382 (0x111E)/Cycle count
•
4374 (0x1116)/Total actuator travel
•
The command
Reset Diagnostic Parameters
can be executed via
Index 2 (0x02)/System Command, Value 228
. The
following indices are reset:
•
4356 (0x1104)/Operating Hours, Subindex 2 (0x02)/Since last reset
•
4357 (0x1105)/Power cycles, Subindex 2 (0x02)/Since last reset
•
4382 (0x111E)/Cycle count
•
4374 (0x1116)/Total actuator travel, Index 2 (0x02)/System Command, Value 228
•
The command
Reset all present alerts
resets all alert notifications. The command can be executed via
Index 2 (0x02)/
System Command, Value 229
.
•
The command
Reset operating hours counter
can be executed via
Index 2 (0x02)/System Command, Value 228
. The
following indices are reset:
•
4356 (0x1104)/Operating hours, Subindex 2 (0x02)/Since last reset
•
The command
Reset power cycles counter
can be executed via
Index 2 (0x02)/System Command, Value 228
. The
following indices are reset:
•
4357 (0x1105)/Power cycles
•
The command
Reset actuator cycles counter
can be executed via
Index 4398 (0x112E)/Reset actuator diagnostics
parameters, Value 2
. The following indices are reset:
•
4382 (0x111E)/Cycle Count
•
The command
Reset total actuator travel
can be executed via
Index 4398 (0x112E)/Reset actuator diagnostics
parameters, Value 1
. The following indices are reset:
•
4374 (0x1116)/Total actuator travel
•
The command
Application reset
can be executed via
Index 2 (0x02)/System Command, Value 129
. This command can
reset the same indices as the command
Restore factory settings
; however, this command has no effect on the identifi-
cation parameters
Index 24, 25, 26
and
64
.
•
The command
Reset trained algorithm parameter
can be executed via
Index 2 (0x02)/System Command, Value 192
.
This command does not reset any diagnostic data or settings, but rather only the measured values of the algorithm. It is
recommended to use this command if the product will be mounted to a different drive. Only two complete piston strokes
are then required for the teach-in process.