Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
DDOC01932 / -
13
INSTALLATION AND OPERATING INSTRUCTIONS:
MFS02-S-KHC-IL
EN / 2023-07-07
11.3 Process data structure
INFORMATION
►
Please note that the value of
Index 16512 (0x4080)/MDC Descr, Subindex 1 (0x01)/Lower Limit
and
Subindex
2 (0x02)/Upper Limit
can change while the sensor is taught the measuring range.
Bit offset
-
Byte 0
Bit 31
Bit 30
Bit 29
Bit 28
Bit 27
Bit 26
Bit 25
Bit 24
Description
Measurement value
Subindex
-
Data type
Integer 16
Bit offset
16
Byte 1
Bit 23
Bit 22
Bit 21
Bit 20
Bit 19
Bit 18
Bit 17
Bit 16
Description
Measurement value
Subindex
1
Data type
Integer 16
Bit offset
8
Byte 2
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Description
Scale
Subindex
2
Data type
Integer 8
Bit offset
7
6
5
4
3
2
1
0
Byte 3
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Description
Qint.X/Alert
Subindex
3
4
5
6
7
8
9
10
Data type
Boolean
11.3.1 General functions
•
The exact position of the piston in the movement range of 50 mm is output via byte 0 and byte 1 and thus bits 16–31.
•
The scaling is output via byte 2.
•
Up to eight switch points can be output via byte 3. Alternatively, alert notifications can be output via byte 3 instead of the
switch points.