Bit 11: UndefinedPosition
Active if the product is not set to TeachPosition, WorkPosition or BasePosition.
Bit 12: DataTransferOK
This bit is used for data transmission using the handshake. Active as soon as the product has taken over the data using the
parameter ControlWord = 1 (decimal).
Bit 13: ControlWord 0x0100
This bit is a direction flag. Active if the last motion task was carried out toward BasePosition.
Bit 14: ControlWord 0x0200
This bit is a direction flag. Active if the last motion task was carried out toward WorkPosition.
Bit 15: Error
Active if the product has an active error. The error message can be determined using Diagnosis.
11.4.12 Diagnosis
The value returned in Diagnosis corresponds to the error code (see "Error Diagnosis" section).
Name
Diagnosis
Data format
UINT16
Permission
Write
Transfer
Cyclical
Value range
0 ... 65535
11.4.13 ActualPosition
ActualPosition corresponds to the current position of the gripper jaws relative to the full stroke.
The value is specified with a resolution of 0.01 mm.
The values can move between the BasePosition (minimum values) and the WorkPosition (maximum values).
With the position measuring system, it is possible to achieve a position accuracy of +/- 0.05 mm.
Name
ActualPosition
Data format
UINT16
Permission
Read
Transfer
Cyclical
Value range
0 to max. jaw stroke of the product
INFORMATION
►
Use the StatusWord to check whether a workpiece has been gripped correctly.
• The position measurement resolution is 0.01 mm.
• The position measurement accuracy is 0.1 mm.
►
During commissioning, be aware of fluctuations around the exact value if you use ActualPosition to detect the
workpiece.