Name
Data format
Access rights Values
Description
0x0123
(291)
ForceMove
UINT8
Read/write
0 to 1
If in DeviceModes 6x, the
ActualPosition is greater
than the WorkPosition,
MovetoWork is not run and
an error is generated
(diagnostics 0x307).
If in DeviceModes 6x, the
ActualPosition is less than
the BasePosition,
MovetoWork is not run and
an error is generated
(diagnostics 0x307).
The move command can be
carried out using the
ForceMove function.
The product is delivered with
ForceMove = 0.
►
Set ISDU 291.0 = 1
to enable the move
command.
• DeviceMode 6x - Actual
-
Position > WorkPosition
- MovetoWork
Ö
This setting is stored in
the product.
ForceMove = 0 Move
command is not executed
(diagnostics 0x307).
ForceMove = 1 Move
command is executed.
• DeviceMode 7x - Actual
-
Position < BasePosition
- MovetoBase
ForceMove = 0 Move
command is not executed
(diagnostics 0x307).
ForceMove = 1 Move
command is executed.
The product is delivered with
ForceMove = 0.
►
When swapping out the
product, write the values
again.
The function is available
starting from Application
Firmware Version
SWA000059_000, see Index
0x0017.