33
11.8.1
Positioning profiles
Modes 50 and 51 can be used for positioning
the product or for form-fit gripping.
WorkPosition
Speed [%]
DriveVelocity
BasePosition
Position [mm]
PositionTolerance (PT) PT
PT
PT
The movement speed is configured using the
DriveVelocity parameter.
The TeachPosition and ShiftPosition
parameters do not have any significance in this
mode because the BasePosition or WorkPo
-
sition is always approached precisely.
If the product encounters an obstacle in this
mode, the movement stops.
The product can be moved from the obstacle
back to the starting position if the command is
switched in the ControlWord.
No defined gripping forces can be generated in
this mode. As a result, friction-locked gripping
is not permitted in this mode.
DeviceMode
Action
ControlWord
50
Positioning to BasePosition or WorkPosition
0x0100/0x0200
51
Positioning without an unlocking operation to BasePosition or WorkPosition
0x0100/0x0200
Positioning profile 50 – standard
The move commands in the ControlWord trigger a movement in the corresponding direction at DriveVelocity.
Positioning profile 51 – high clock rate
Behaves like mode 50, but when the gripping movement starts, the unlocking operation is omitted. This enables a shorter
response time.
►
Ensure that no gripping force is acting on the gripper jaws.
Ö
The movement may stop as a result.
INSTALLATION AND OPERATING INSTRUCTIONS:
GEH6000IL/GED6000IL
DDOC00212 / p
EN / 2022-05-01
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com