Name
Data format
Access rights Values
Description
0x0017 (23)
Firmware version
STRING
Read
-
Firmware version consists of
four parts in the following
sequence:
• Communication Firmware
• Example:
• Type: SWA000058
• Version: R00
• Application Firmware
• Example:
• Type: SWA000059
• Version: P00
• Motor Control Firmware
• Example:
• Type: SWA000060
• Version: D00
• Parameters
• Example:
• Type:
PAR000059_04
• Version: 10030
0x0040
(64)
Status
UINT16
Read
0 ... 65535
Reflection of the process
data
0x0041
(65)
Diagnosis
UINT16
Read
0 ... 65535
Reflection of the process
data
0x0042
(66)
Cycle counter
UINT32
Read
0 ... 4294967295
Current numbers of cycles
0x0043
(67)
Temperature
UINT16
Read
0 ... 100 °C
Current temperature
0x0044
(68)
ControlWord
UINT16
Read
0 ... 65535
Reflection of the process
data
0x0045
(69)
Error code
STRING
Read
-
Current error code
0x0046
(70)
Error counter
UINT32
Read
0 ... 4294967295
Current error counter
0x0100
(256)
Actual position
UINT16
Read
0 to max. jaw
stroke of the
product
Reflection of the process
data
0x0101
(257)
TeachPosition
UINT16
Read
0 to max. jaw
stroke of the
product
Reflection of the process
data
0x0102
(258)
WorkpieceNo
UINT8
Read
0 ... 32
Reflection of the process
data
15 Table with acyclic data (ISDU)
INFORMATION
IO-Link distinguishes between cyclical process data (PDU) and acyclic data (ISDU).
Access to acyclic data is not arranged very conveniently for all control system and IO-Link master combinations.
For this reason, the product can be used without acyclic data. This makes it as easy as possible to control the
product.