SR981S/SR982S operation manual of solar pump station
Page 56 of 85
8.5.4.2
DTS2
Standard temperature difference of
pump 2 (for pump 2 speed
adjustment )
2
o
C
~
30
o
C
8
o
C
8.5.4.3
RIS2
Gain for circulation pump 2 (for
pump 2 speed adjustment)
1
o
C
~
20
o
C
1
o
C
8.5.10
OHQM
Thermal energy measuring
ON/OFF
OFF
8.5.9
FTYPE
Flow meter type 1 selection
01: mechanical flow meter
02: Electronic flow meter
01: mech.
flow meter
8.5.9
FTYP2
Flow meter type 2 selection
01: mechanical flow meter
02: Electronic flow meter
01: mech.
flow meter
8.5.10.1
FMAX
Flow rate
0.1
~
20L/min
2.0L/min
8.5.10.2
MEDT
Type of heat transfer liquid
00: Water
01: Propylene glycol
02: Glycol
03: Tyfocor LS/G-LS
01: Propylene
glycol
8.5.10.3
MED%
Concentration of heat transfer
liquid
20
~
70
40
8.5.11
PRIO
Tank priority
00~02, Su1, Su2
01
8.5.11.1
tRUN
Interval heating run-on time
1
~
30 minute
15minute
8.5.11.2
tSTP
Interval heating run-off time
1
~
30 minute
2 minute
8.5.12
INTV
Pump Intermission function
ON/OFF
OFF
8.5.12.1
IRUN
Pump interval run-on time
2
~
60 minute
30minute
8.5.12.2
ISTP
Pump interval run-off time
5
~
120 seconds
15 seconds
8.5.13
COOL
Tank cooling function
5
o
C
~
120
o
C
95
o
C
8.5.14
AHO
Switch-on temperature of
thermostat function
0
~
95
o
C
50
o
C
8.5.14
AHF
Switch-off temperature of
thermostat function
0
~
95
o
C
55
o
C
8.5.15
BYPR
By-pass pipe ( high temperature)
OFF/ON
ON
8.5.1 DVWG Anti legionnaires' function
Description:
In order to avoid occurring bacteria in water tank when the temperature of tank is lower for
a long time, controller will check the temperature of tank every 7 days in a period
automatically, if the temperature of tank is never over 70
o
C during this period, then at the
factory default time of 01:00 on seventh day, auxiliary heating system is triggered
automatically to heat water until its temperature rises up to 70
o
C, bacteria is killed by high