SR981S/SR982S operation manual of solar pump station
Page 54 of 85
switch-off condition, corresponding P1 or P2 is ceased.
Setup steps:
To access main menu TEMP, then select submenu MAX2,
“MAX2 60
o
C” shows on the screen.
►Press “SET” button, parameter “60
o
C” blinks
►Press
“
” button to adjust the value of
maximum temperature of tank , adjustable range is
(
MIN2+2
o
C)
~ 95
o
C, default set is 60
o
C
► Press “ESC”
button to exit the menu or wait for 20 seconds to exit, parameters are
saved automatically.
8.4.11 MIN2 Minmium switch-on temperature for heat transfer between heat
exchanger and tank
Setup steps:
To access main menu TEMP, then select submenu MIN2,
“MAX2 30
o
C” shows on the screen.
►Press “SET” button, parameter “30
o
C” blinks
►Press
“
” button to adjust the value of
maximum temperature of tank, adjustable range is 10
o
C
~ (MAX2-2
o
C), default set is 30
o
C
► Press “ESC”
button to exit the menu or wait for 20 seconds to exit, parameters are
saved automatically.
8.4.12 C
_
F Switch between Celsius and Fahrenheit
Setup steps:
To access main menu TEMP, then select submenu C_F,
“C_F
o
C” shows on the screen,
►Press “SET” button, displayed parameter
o
C blinks on
the screen
►Press “ ” button, to select Celsius or Fahrenheit
temperature unit, default set is
o
C
► Press “ESC” button to exit the menu or wait for 20 seconds to exit, parameters are