SR981S/SR982S operation manual of solar pump station
Page 38 of 85
set the switch-on time of heating is at 17:00, but switch-off time of heating is 6:00,
then this setting doesn’t take effect, that means within this time section, heating
function doesn’t work. The correct set is like following: it should be divided into
two time sections, one time section is from 17:00 to 23:59, the other time section is
from 00:00 to 06:00.
Setup steps:
Under standby status,
► Press “SET” button ,repress button,to select THET menu.
► Press “SET” button, “tH 1o 04:00” shows on the screen, access the submenu of the
switch-on time and temperature for the first time heating.
► Press “SET” button, hour “04” blinks on the screen; the switch-on time and temperature
for the first time heating function can be set.
► Press “ ” button to adjust hour.
► Repress “SET” button, minute “00” blinks on the screen.
► Press “ ” button to adjust minute of time.
► Repress “SET” button, temperature “40
o
C” blinks on the
screen.
► Press “ ” button, to set the switch-on temperature of heating.
► then, press “ESC” to exit and confirm setting.
► Press “ ” button, “tH 1F 05:00” shows on the screen, access the submenu of the
switch-off time and temperature for the first time heating
function.
► Press “SET” button again, hour “05” blinks on the
screen.
► Press “ ”button to adjust hour of time.
► Repress “SET” button, minute “00” blinks on the screen.
► Press “ ”button to adjust minute of time.
► Repress “SET” button, temperature “45
o
C” blinks on the screen.
► Press “ ”button, to set the switch-off temperature of heating.