SR981S/SR982S operation manual of solar pump station
Page 46 of 85
►Press “SET” button, “04
o
C” flashed, the switch-off temperature difference can be set.
►Press “ ” button, to adjust the value of switch-off DT F, adjustable range : 0
o
C
~
(On-2
o
C), factory setting is 4
o
C
►Press “ESC” button to exit this setting, or after seconds to exit automatically, parameter
is saved automatically.
Note:
due to different system, maximum 3 temperature differences (DT1o, DT1F), (DT2o,
DT2F), (DT3o, DT3F) can be set, setup steps are same above steps.
8.4 TEMP Temperature main menu
For solar system, the factory set parameters are for the best operation condition, which is
fully integrated into the entire solar system. But these parameters can also be set
individually to cater the special requirements, please carefully observe the operation data
of system components after setting.
Note:
Parameters that can be set rely on the system design; it means not all the
parameters are suitable for all solar systems.
Following submenu can be accessed though TEMP main menu.
Paragra
ph
Tem.
Code
Function of temperature
Adjustable range
Factor
y set
Function
exit tem.
8.4.1
EMOF
Maximum switch-off temperature of collector
(ON+3
o
C)~200
o
C
130
o
C
8.4.1
EMON
Maximum switch-on temperature of collector
(OFF-3
o
C)~197
o
C
120
o
C
8.4.2
CMX
Maximum limited temperature of collector
(collector cooling function)
90
o
C ~180
o
C
110
o
C
107
o
C
8.4.3
CMN
Low temperature protection of collector
0
o
C~90
o
C
OFF
8.4.4
CFR
Frost protection temperature of collector
-10
o
C~10
o
C
OFF
8.4.5
REC
Re-cooling temperature of tank
OFF
8.4.6
SMX1
Maximum temperature of tank 1
2
o
C~95
o
C
60
o
C
58
o
C
8.4.7
SMX2
Maximum temperature of tank 2
2
o
C~95
o
C
60
o
C
58
o
C
8.4.8
MAX1
Maximum switch-off temperature for heat
transfer between tank and heat return
(MIN1+2
o
C)~95
o
C
60
o
C
8.4.9
MIN1
Minimum switch-on temperature for heat
transfer between tank and heat return
10
o
C~(MAX1-2
o
C)
30
o
C
8.4.10
MAX2
Maximum switch-off temperature for heat
transfer between heat exchanger and tank
(
MIN2+2
o
C
)~
95
o
C
60
o
C
8.4.11
MIN2
Minimum switch-on temperature for heat
transfer between heat exchanger and tank
10
o
C
~(
MAX2-2
o
C
)
30
o
C
8.4.12
C - F
Switch between Celsius and Fahrenheit
o
C
~
o
F
o
C