3 Product overview
3.1 Operational area
The devices are designed as temperature control units for stable compartments in single or central
exhaust air installations.
•
In
installations with single suction
, fans,
aps andheatings are controlledvia the outputs.
•
In
central exhaust installations
, these devices are used in combination. The devices controls
the exhaust air
ap andthe heatings for one compartment. At the same time the exhaust air
volumes of all the compartments connectedare signaledto a
Master*
. The speedis calculated
from the sum of the exhaust air volumes and the fans connected are readjusted.
In order to be able to network several devices, these are equipped with a bus interface. In this way, for
example, the supply air temperature sensor connectedto the
Master*
can be communicatedto all
system users. Fault messages on stall devices are transmitted and displayed as a group fault; in
addition the total exhaust air volume of the ventilation system is determined.
UNIcon Type CTE/AH(X)-L
The control module Unicon type CTE/A(X)H-L has signal outputs e. g. for the control of ETAvent fans
anddamper control motors.
Acontrol Type PTE-6AHQ(X)-L and PTE-10AHQ(X)-L
The voltage controllers model range Acontrol type PTE-6AHQ(X)-L and PTET-10AHQ(X)-L have an
operating output for voltage-adjustable 1~ motors with a maximum control current of 6 A or 10 A.
Master*
A device which controls andmonitors the bus communication andperforms central control functions
3.2 Maintenance
The device must be checked for soiling and, if necessary, cleaned in periodic intervals.
3.3 Transport
•
The device is packed ex factory to suit the transport method previously agreed.
•
Always use the original packaging materials when transporting the device.
•
Avoid shocks and impacts to the device during the transport.
•
During manual handling the human lifting and carrying restrictions must be observed and
adhered to.
3.4 Storage
•
The device must be stored in its original packaging in a dry and weather-proof room.
•
Avoidexposure to extreme heat andcold.
•
Avoidover-long storage periods (we recommenda maximum of one year).
3.5 Waste disposal / recycling
Disposal must be carried out professionally and environmentally friendly in accordance with the legal
stipulations.
Operating Instructions
UNIcon / Acontrol
Product overview
L-BAL-E051-GB 1035 Index 003
Part.-No. 00163311-GB
7/83