7.13
|
Installation
|
Diverse
◄
Diverse
↑
|
ESC
|
P
↓
7.13.1
Displaymode
Displaymode
Displaymode
De
nition of the additional value in the standard display (right
eldxx_ _:)
|
OFF
|
: right digit not assigned
|
1
|
: SH = modulation shutter (throttle shutter)
factory setting
|
2
|
: HE = modulation heat exchanger (0 % = Bypass shutter
completely open, 100 % = Bypass shutter closed)
|
3
|
: FA = modulation fresh air fan for heat exchanger
|
4
|
: FAS = Fanlevel Freshairshutter
|
5
|
: GRP = Group control
|
6
|
: RH = Relative Humidity (in combination with 0 - 10 V
signal from humidity sensor)
|
7
|
: FN = temperature piglet nest (Heating2 in mode 3 or 4
otherwise display
“
ERROR
”
|
8
|
: ZRS = central exhaust air total
|
9
|
: GR1 = fan level group 1
|
10
|
: ZRS - GR1 - GRP - WT - WTZ - ZLK = values for central
exhaust air alternating for approx. 4 seconds.
|
11
|
: HBS = modulation heat exchanger Bypass shutter (0 %
= Bypass shutter completely closed, 100 % = Bypass com-
pletely open)
S:20.0
°
xx:_ _
7.13.2
Switch mode
Switch mode
Switch mode
The factory-set switch mode is
|
OFF
|
. This means that the control unit is active in all
switch positions, i.e. overtemperature/undertemperature messages also in switch posi-
tion
“
0
”
and
“
100 %
”
!
In switch mode
“
ON
”
the control unit is switchedoff in switch position
“
0
”
(Stop symbol).
7.13.3
Preheat operation, Stall washing Operation
The operating modes
“
Wash
”
and
“
Pre-heat
”
can be activatedin the Quick Menu under the setting
“
Stall
”
or by external switching contacts at the digital inputs.
The activation by the digital inputs has priority over the settings in the
“
Stall
”
menu.
ventilation in Stall washing operation
Wash ventilation
Wash ventilation
The ventilation is set to 50 % in wash mode at the factory. This value becomes active
when the device is in the wash mode.
Setting range: 0...100 %
Factory setting: 50 %
Operating Instructions
UNIcon / Acontrol
The Installation menu
L-BAL-E051-GB 1035 Index 003
Part.-No. 00163311-GB
41/83