heating in stall washing operation
Wash setpoint
Wash setpoint
The heating setpoint of the stall is set to 15.0
°
C in wash mode at the factory.
This value becomes active when the device is in the wash mode.
setting range: 0.0..70.0
°
C
Factory setting: 15.0
°
C
Heating in preheat operation
Preheat setpoint
Preheat setpoint
This value becomes active when the device is in the heat mode (D1 function =
|
2D
|
andD3 function =
|
3D
|
for operation with external switch, switch position 2).
setting range: 0.0..70.0
°
C
Factorysetting: 0.0...20.0
°
C
7.13.4
External switch extension
For Stall ON/OFF, Stall preheat, Stall washing
With the appropriate programming an external 3-step switch can be connectedat the digital inputs D1
andD3
In this way a special wash mode and heat mode can be activated in addition to stall ON / OFF.
Necessary Settings
•
- D1 function =
|
2D
|
•
- D3 function =
|
3D
|
S1
S2
S3 Mode
0
0
Stall off
1
0
0
Stall on
0
1
0
Cot Preheating
0
0
1
Cot Washing
0 switche opened
1 switches closed
1N4148,
1N4002
S2
S1
S3
01.10.2008
v_ext_schalt_erw_cte_pte.vsd
D3
D3
D1
D1
The switch with the switching contacts
“
S1-S2-S3
”
anddiodes (e.g. 1N4148, 1N4402) optional for activation of the operating
mode
“
Stall Wash
”
.
Operating Instructions
UNIcon / Acontrol
The Installation menu
L-BAL-E051-GB 1035 Index 003
Part.-No. 00163311-GB
42/83