Important !!! The above stated values only apply to LUPROSIL® or media with
similar properties.
At LUPROSIL® NC and NC 64, the flow rate values depend on the
temperature.
Table 3 (according to BASF)
Required quantities for Luprosil® (in %) for wet grain (whole grains), all grain
types including corn:
Moisture Content
Conservation Period in Months
in %
1
1-3
3-6
6-12
Up to16
0,35
0,45
0,50
0,55
16-18
0,40
0,50
0,55
0,65
18-20
0,45
0,55
0,65
0,75
20-22
0,50
0,65
0,75
0,85
22-24
0,55
0,70
0,85
0,95
24-26
0,60
0,80
0,95
1,05
26-28
0,70
0,90
1,05
1,15
28-30
0,80
1,00
1,15
1,30
30-32
0,90
1,10
1,25
1,45
32-34
1,00
1,20
1,35
1,60
34-36
1,10
1,30
1,50
1,75
36-38
1,25
1,45
1,65
1,90
38-40
1,40
1,60
1,80
2,05
40-42
1,55
1,75
1,95
2,20
42-44
1,70
1,90
2,10
2,35
44-46
1,85
2,05
2,25
2,55
46-48
2,00
2,20
2,40
2,75
48-50
2,15
2,35
2,60
2,95
If it is intended to further convey acid-conserved grain with a grain blower
immediately following the treatment, an intermediate storage of one hour is required.
If the immediate
downstream connection of the blower to the dosing device can not
be prevented, the required quantity stated in the table must be increased by at least
10 % according to BASF.
Summary of Contents for PKT 452
Page 2: ......
Page 4: ......
Page 13: ...Abb 4 Kontaktnehmer Kontaktnehmer Mitte Schwimmeroberkante Kontaktgeber ...
Page 22: ...22 b Bildliche Darstellung des Schaltkastens Abb 9 K 3 K 1 K 2 ...
Page 25: ...25 Bild 1 7 8 50 5 10 6 4 4 3 11 13 Bild 2 9 12 7 8 27 ...
Page 26: ...26 Bild 3 Bild 4 15 13 11 4 9 10 14 4 4 7 6 9 ...
Page 31: ......
Page 34: ...34 ...
Page 36: ...36 ...
Page 45: ...45 Diagram 13 Contact Maker Contact Maker Center Cwenter Floater Upper Edge Contact Maker ...
Page 54: ...54 b Graphic Presentation of the Control Box Diagram 18 K 3 K 1 K 2 ...
Page 57: ...57 Image 1 7 8 50 5 10 6 4 4 3 11 13 Image 2 9 12 7 8 27 ...
Page 58: ...58 Image 3 Image 4 15 13 11 4 9 10 14 4 4 7 6 9 ...
Page 63: ...63 ...