B. Specifications
134
MALES
FEMALES
11"
9.5"
P1 - COM 4
P1 - COM 2
P1 - COM 3
P1 - COM 1
P1 - J2
P1 - LPT
P1 - J1
2 - 6
1 - 1
3 - 2
4 - 7
5 - 3
6 - 8
7 - 4
8 - 9
9 - 5
10 - NC(+5)
11 - 1
12 - 6
13 - 2
14 - 7
15 - 3
16 - 8
17 - 4
20 - NC(+5)
18 - 9
19 - 5
21 - 1
22 - 6
23 - 2
24 - 7
25 - 3
26 - 8
27 - 4
28 - 9
29 - 5
30 - NC(+5)
31 - 1
32 - 6
33 - 2
34 - 7
35 - 3
36 - 8
37 - 4
38 - 9
39 - 5
40 - NC(+5)
41 - 1
42 - 6
43 - 2
44 - 7
45 - 3
46 - 8
NC - 4
NC - 9
NC - 5
47 - 1
48 - 14
49 - 2
50 - 15
51 - 3
52 - 16
53 - 4
54 - 17
55 - 5
56 - 18
57 - 6
58 - 19
59 - 7
60 - 20
61 - 8
62 - 21
63 - 9
64 - 22
65 - 10
66 - 23
67 - 11
68 - 24
69 - 12
70 - 25
71 - 13
72 - 1
73 - 6
74 - 2
75 - 7
76 - 3
77 - 8
78 - 4
79 - 9
80 - 5
40
80
AMP
104892-8
Receptacle
w/ Latch
11"
AMP
104891-8 (2 Places)
Terminating Covers
P1
TB ANSLEY 622-1030
10-Pin Female
w/ Polarization (4 Places)
COM 4
COM 3
COM 2
COM 1
TB ANSLEY
622-09PMI
9-Pin Male
(4 Places)
J2
LPT
J1
Truncate Conductors 10, 20, 30, 40
After 10-Pin Female; Do Not Connect
to 9-Pin Male.
TB ANSLEY
622-09SMI
9-Pin Female
(2 Places)
TB ANSLEY
622-25SMI
747052-2
25-Pin Female
40
1
TB ANSLEY: 171-40
Gray, 40 Wire, 28 Gauge
Stranded Flat Cable or Equiv. (2 Places)
1
5
6
9
1
6
5
9
1
6
1
5
9
6
5
9
Justify 6 Conductors to Pin 1
1
6
5
9
1
14
13
25
1
6
5
9
1
2
1
1
1
1
2
2
2
Connect to 10-Pin Female for +5V, no connection to 9-Pin Male (COM1-4)
Justify 6 Conductors toward Pin 1.
3"
Notes:
1) On side of connector P1 heat dry permanently stamp
the following text: 90200-0.
KEEP CABLE
AS SINGLE PIECE
FOR FIRST 3"
BEFORE
SEPARATING
ZT 90200 Quad Serial and Printer Cable For ZT 8904 and ZT 89CT04