background image

 

 

 

 

Intelligent Radio Interface Module 

 for Motorola iDEN i365 

 

 

025-9623 D3 

Summary of Contents for 025-9623 D3

Page 1: ...Intelligent Radio Interface Module for Motorola iDEN i365 025 9623 D3...

Page 2: ...at Zetron s option after return of such items by buyer to Zetron Shipment shall be paid for by the buyer No credit shall be allowed for work performed by the buyer Zetron Products or Zetron Accessorie...

Page 3: ...C Class A User Information This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea...

Page 4: ...discharge device is used to prevent damage to electronic components Do not attempt internal service of equipment unless another person capable of rendering aid and resuscitation is present Do not work...

Page 5: ...rements 19 Connecting to the iRIM 20 Configuring System Parameters 21 Configuring Channel Parameters 22 Channel A or Channel B Parameters 22 Configuring Console Audio Levels 23 Configuring the Digi On...

Page 6: ...rting to a Previous Firmware or Configuration Version 43 Rebooting the iRIM 43 Logging Out 43 FTP Access 43 Configuration Reference 44 System Parameters 44 Channel Parameters 46 Parameters Specific to...

Page 7: ...e remote function tone sequences The iRIM iDEN i365 Adapter provides the appropriate connections to the radio enabling the radios to communicate with the iRIM to be powered by the adapter and to charg...

Page 8: ...FSK signaling AGC automatic gain control on transmit audio Control of two radios per iRIM Modular connectors and pre set levels for easy installation Configurable over Ethernet using a standard web b...

Page 9: ...erface cables Ethernet cables connect the iRIM Adapters to the iRIMs The supplied RJ 45 cable or any standard eight conductor RJ 45 cable such as an Ethernet cable connects the iRIM to a punchdown blo...

Page 10: ...configuration parameters can be set according to your preferences However the following configuration parameters must be set in each iDEN radio to allow proper operation with the console The baud rat...

Page 11: ...skip to the next section Connecting the Components on page 12 The iRIMs and iRIM adapters are designed to be either free standing devices or with a special top cover rack mount devices A free standin...

Page 12: ...the top 3 Slip the unit s ears over the threaded studs on the back of the rack mount plate 4 Secure the unit with the four provided 4 40 nuts Repeat for additional units 5 Install the mount plate and...

Page 13: ...onnecting the Components 13 Figure 3 iRIM connection diagram in a DCS 5020 system Note When looking at the back of the units as shown in Figure 3 pin 1 is on the left for all ports shown in the diagra...

Page 14: ...tandard Ethernet Cables Earth Ground 12 VDC 10 5 to 16 VDC 3 2A minimum with two radios 1 0A for iRIM plus adapter 1 1A for each radio Cable P N 709 7964 12VDC Radio A iRIM Radio A iRIM Radio B Radio...

Page 15: ...ort on the iRIM to the iRIM Radio A port on the iRIM adapter as shown in Figure 3 2 Use cable 709 0065 or a standard CAT5 Ethernet patch cable to connect the Radio B port on the iRIM to the iRIM Radio...

Page 16: ...et network or an Ethernet crossover cable P N 709 0130 connect the Network Port of the iRIM to the Acom EIU For more information refer to Acom Ethernet Interface Unit P N 025 9620 Consoles Port To con...

Page 17: ...le Audio Channel B 3 Green White RXA RIM to Console Audio Channel A 4 Blue TXA Console to RIM Audio Channel A 5 Blue White TXA Console to RIM Audio Channel A 6 Green RXA RIM to Console Audio Channel A...

Page 18: ...Installation 18 025 9623 D3...

Page 19: ...ting to the iRIM on page 20 Configuring System Parameters on page 21 Configuring Channel Parameters on page 22 Configuring Console Audio Levels on page 23 Requirements The Zetron console is already co...

Page 20: ...68 0 5 the network mask to 255 255 255 0 and gateway address to 192 168 0 2 4 Open a web browser such as Internet Explorer on the configuration PC Open a connection to this URL 5 http 192 168 0 133 Th...

Page 21: ...connected to a network contact your IT department to get settings compatible with your particular network 5 The Password field changes the password used to log into the iRIM menus It is not strong by...

Page 22: ...age 2 Click the Channel A Parameters button This will bring up the Channel A Configuration page 3 First select iDEN Handheld from the Radio Type drop down menu Once you ve selected a radio the page wi...

Page 23: ...tions on this being the loudest tone The level for the HLGT should be less than the Peak Level From Console Audio Level From Console defines the level of the average voice audio from the console Audio...

Page 24: ...to measured value in Step 2 which corresponds to a 60 channel deviation The iRIM default for the Audio Level From Console is 7 dBm 8 Set the Audio Level To Console to the sum of the line loss measured...

Page 25: ...ded it has preconfigured IP address labels attached then skip to the second phase Configuration Using a Browser on page 34 The second phase is carried out with the browser installed on your PC such as...

Page 26: ...IA 232 serial port Figure 6 Digi One SP Serial Port Switch set to EIA 232 When the switch is configured as shown in Figure 6 that is switch 1 up and switches 2 3 and 4 down the module is set for EIA 2...

Page 27: ...odule can be programmed on a different network than the one it will eventually be installed in like the network in your shop as long as the IP address assigned is also available on that network If thi...

Page 28: ...le and then into a wall socket Do not expect the power LED to come on right away 5 Plug the Ethernet cable into the RJ 45 jack on the module and plug the other end of the cable into any available port...

Page 29: ...Digi Software Tool 29 3 Once the software has scanned the network available to it it will display the IP and MAC addresses of any Digi One units it finds Select the MAC address for the unit you are co...

Page 30: ...g example these have been filled in with the settings from Table 5 Please note that the boxes for DNS Server Domain and Host Name should still be blank When you are finished click on Next 5 When the S...

Page 31: ...screen to pick a more specific scenario Open the Scenario List box and select Outgoing TCP Connection as the scenario type Click on Next 7 When the following screen opens enter the TCP Connection set...

Page 32: ...ta Bits 8 Parity None Stop Bits 1 Flow Control Hardware 9 After you finish selecting and setting up the scenario the wizard will display a screen that allows you to scroll through the settings you hav...

Page 33: ...d to do anything until the process is finished The program will advance to the next screen automatically 11 This screen confirms that you have successfully configured the Digi One SP module to perform...

Page 34: ...units will be installed this information will always be the same for any Kenwood Radio Interface Module installation STOP Warning Good cybersecurity practice requires changing the default password imm...

Page 35: ...would be 192 168 25 135 Press ENTER and the log on dialog box that follows should appear 2 Enter the default user name and password into the appropriate boxes in the dialog and click on the OK button...

Page 36: ...reen Notice the Basic and Advanced options that appear in the bottom of the window 4 Click on the option Advanced Serial Settings As shown in the following window configure the serial port parameters...

Page 37: ...n This opens the System Configuration window Use the down arrow to open the list and set the parameter Optimization to read Latency When you have finished be sure to click on the Apply button before y...

Page 38: ...onnecting the unit from the network and removing power from it If you wish to save a snapshot of the modules programming either for backup purposes or to facilitate the cloning of similar units please...

Page 39: ...web browser save and restore the configuration with an FTP client and view the configuration and firmware versions In this chapter Requirements on page 39 Setup on page 40 HTTP Access on page 41 FTP...

Page 40: ...vides the highest level of security since the iRIM is only accessible by that PC and not over a general network 1 The first step is to connect the iRIM s Network jack to the PC s network card with a s...

Page 41: ...pdates and configuration changes Connecting The iRIM may be accessed by typing its IP address into the Address bar in Internet Explorer 6 0 or later The opening page will ask for the password After en...

Page 42: ...le units or for backing up the configuration To save a copy of the configuration to disk follow the instructions on the main page by right clicking the this link option and selecting the Save Target A...

Page 43: ...until the iRIM is rebooted This may be accomplished by pressing the Reboot Radio Interface Module button on the main page Rebooting the iRIM There are times when it is desirable to reboot the iRIM re...

Page 44: ...files available for download 4 Enter bye to end the session Note The FTP connection will time out in two minutes if no action is taken 5 To upload a saved configuration files Make sure that it is nam...

Page 45: ...can be any valid netmask in the format of xxx xxx xxx xxx where each xxx grouping can be any number from 0 to 255 The netmask chosen must be the correct netmask for the network that the iRIM resides...

Page 46: ...duplicated on both the Channel A Configuration Page and the Channel B Configuration Page They may be set independently for each channel Radio Type The radio type is selected from a drop down list If n...

Page 47: ...0 775 VRMS The default is 10 dBm Audio Level From Console dBm Audio Level From Console specifies the level at which average voice audio from the console system reaches the iRIM A 1 kHz tone at this l...

Page 48: ...el To Radio dBm Audio Level To Radio specifies the level at which average voice audio from the iRIM is sent to the radio A 1 kHz tone at this level will be sent over the air at 60 channel deviation Th...

Page 49: ...ias 1 20 A Talkgroup Alias is used to replace generic Talkgroup numbers with names that are easier to understand during console operation The aliases configured in the iRIM are passed to the console w...

Page 50: ...arging voltage present for Radio A When off there is insufficient voltage for charging the battery Radio B Green Battery charging voltage present for Radio B When off there is insufficient voltage for...

Page 51: ...ks red when the iRIM sends a data packet to the radio It is normal for this indicator to blink even in an idle state because the iRIM continuously polls the radio on the serial interface Radio RX Red...

Page 52: ...0 amp for iRIM 1 1 amp per radio Mounting Co located with the radio Desk or rack mount optional Operating temperature 0 60 C 32 140 F Size 1 5 x 7 75 x 10 25 inches HxWxD Tone Remote Interface Interf...

Page 53: ...Tone Remote Interface 53...

Page 54: ...l port 26 connecting to the network 28 initial config with Digi software 28 F Features 8 FTP Access 43 G Gateway 45 Guard Tone To Console On COR 47 H HTTP Access 41 I Installation 9 IP Address configu...

Page 55: ...Index 55 TX Voice Delay 46...

Reviews: