Service control.
(Mark the box for actions performed for each. service point.)
Signature...............................................
Date............................
Company stamp
Service-
points
Comments / Actions
C=Check R=Replace L=Lubrication * If the lift has the equipment **If the service kit contains the detail
Comments
OK
Service points
Information
See instructions for
resp. lift models
Mecanics (Visual inspection of any cracks and / or damage)
IE-0110
C
1.1 Mountng bracket
Any cracks / damage, Torques
IE-0105 / IE-0104
C
1.2 Support frame
Any cracks / damage, drainage holes
IE-0105
C
1.3 Liftarm
Any cracks / damage
IE-0105
C
1.4 Platform
Any cracks / damage
IE-0105
C
1.5 Bumper bar
Any cracks / damage, Torques
IE-0105 / IE-0104
C
1.6 Cylinders
Any cracks / damage, gaiters
IE-0105
R
1.7 Support wheel*
Replace in connection with control of pivot bolts
C
1.8 Pivot bolt, bushing (all)
Wear and tear, Torques
IE-0105 / IE-0104
C
1.9 Slide system*
Any cracks / damage,Torques, funktional
control
IE-0105 / IE-0104
L
1.10 Lubrication
All lubrication points
IE-0101
C
1.11 Sealings against bodywork*
Wear and tear, condition
IE-0106
Hydraulics (sequence) of an oil change (Visual inspection of oil leak on the
entire hydraulic system)
IE-0109
C
2.1 Main fuse
Cleanliness, contact surfaces
IE-0103
R
2.2 Hydraulic oil
Oil, Strainer, o-ring tank,
IE-0102
R
2.3 Oil filter*
Changes at XL-Service. Every three years**
IE-0102
R
2.4 Hydraulic hoses
Also replace the supplied rubber steel washers IE-0104
R
2.5 Solenoid
Changes in connection with oil change
R
2,6 Filler cap
Changes in connection with oil change
C
2.7 The system’s leakproofness
Hydr.connection, -unit+tank, cyl. torques
IE-0104
C
2.8 Pressure Relief Valve
Valve should open when tilting against body,
check pressure if not opening.
IE-0108
C
2.9 Velocity lifting, lowering, tilting
That the lifts speed is within the correct range
IE-0111
Electrical equipment (check all the points cable and interfaces)
C
3.1 Main power cable, ground cable
Wear and tear, attachment, contact surface
IE-0103
C
3.2 Control units
All functions of all control units
IE-0103
C
3.3 Connection box for control units
Tightness, cleanliness
IE-0103
R
3.4 Circuit card**, Relay**
Function, connections, wear and tear **Change
if incl. in service kit
IE-0103
C
3.5 Alarm for open platform
That the lamp shine when platform is not closed IE-0103
C
3.6 Battery voltage, vehicle and lift
inactive
Difference between the battery and hydraulic
unit (not more than 6% dfference)
IE-0103
C
3.7 Cabin switch*
Functional test
IE-0103
Signs, stickers (Visual inspection of the function and interpretable)
R
4.1 Warning flags, -tape
Replace flag and profile
IE-0107
C
4.2 Load chart
1 pc on platform, 1 pc outside control unit
IE-0107
C
4.3 Working area
Sticker on platform
IE-0107
C
4.4 Instruction control units
Outside control unit
IE-0107
C
4.5 Type plate
Is firmly attached and is INTERPRETABLE
IE-0107
Service Protocol XL-Service Incl. replacement of parts in Service Kit
Note: If comment is marked for any of the service points;
complete the task below
Inspection performed:
Actions performed:
Signature.............................................
Date............................
Company stamp
73020TL
Customer:
Vehicle:
Reg.No:
Lift model: Prod.No:
Year 3