65
5.5
Lubrication
5.5.1
General
Check all grease nipples for damage and function. Defective grease nipples must be re-
placed. If grease cannot be charged even if a new grease nipple is fitted, the bearing must
be removed. Contact service workshop. Use LE lubricant 4622.
See lubrication instruction IE-0101.
5.5.2
Interval
At a minimum, lubrication must be done every 3 months. More frequent intervals may be
necessary when driving in aggressive surroundings or the lift is washed often. Contact
ZEPRO for advice.
5.5.3
Before lubrication
Before lubricating, clean the lift, especially the lubrication points and grease nipples.
5.5.4
Correct design
Lubrication must be carried out such that a ring of grease is visible on both sides of the
bearings to protect against the intrusion of water, salt, sand and dirt. See illustration below.
Lubrication must be carried out such that a ring of grease is visible on both sides of the bearings.
Service and maintenance