background image

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

 

 

 

IDAC

 

 

 

 

 

 

 

Access Controller for Installation in Door 

 
 

 

 

 

 

 

ZVIIDAC 

 

U

S

E

R

 M

A

N

U

A

L

 

 

 

 

  

dsñkmfroi 

 

 

 

Application Program Version: 2.0 

 User manual edition: [2.0]_a 

 

 

 

www.zennio.com

   

 

 

 

 

 

 

Summary of Contents for IDAC

Page 1: ...IDAC Access Controller for Installation in Door ZVIIDAC USER MANUAL ds kmfroi Application Program Version 2 0 User manual edition 2 0 _a www zennio com...

Page 2: ...Configuration 7 2 1 General 7 2 2 Indoor Module 9 2 2 1 Configuration 9 2 2 2 Backlight 11 2 2 3 Room State Buttons 11 2 2 4 Touch Locking 12 2 2 5 Sounds 13 2 2 6 Ambient Luminosity Sensor 15 2 3 Out...

Page 3: ...er the correct reading of a NFC card or BLE key data Access Locale o New binary object to inform if accesses granted during a KNX bus failure Access Offline access o Possibility to choose the action w...

Page 4: ...us Battery charging system and power supply to KNX bus by means of retractable metal contacts Outdoor module with rooms access control functionality using Cards with NFC Near Field Communication techn...

Page 5: ...mode In such case the programming LED will blink in red colour For detailed information about the technical features of the device and about the installation process please refer to the corresponding...

Page 6: ...it has power supply through a rechargeable battery although of course there will be no communication with the KNX bus Nevertheless note that to reduce the battery consumption All LED are turn off aft...

Page 7: ...sabled enabled 1 incorporates a one bit object to the project Heartbeat Object to Send 1 that will be sent periodically with a value of 1 to notify that the device is still working still alive Note Th...

Page 8: ...ion to the objects of the access control module the following General Scene Receive and General Scene Send objects for respectively receiving and sending scene values from to the KNX bus whenever it i...

Page 9: ...1 CONFIGURATION In the Configuration tab of the Indoor Module the general configurable parameters of the module are displayed Most of them are checkboxes to activate other functionalities ETS PARAMET...

Page 10: ...tarted in activity state after a download Time to Consider Inactivity 1 65535 s min h time that must elapse since the last press and or proximity detection to consider inactivity state and to set the...

Page 11: ...room is Normal or Make Up Request and the button is pressed it is activated Do Not Disturb If the current state of the room is Do Not Disturb and the button is pressed it is activated Normal Double t...

Page 12: ...1 ds during this time no press will be considered LED Color color of the LED associated to the button when the corresponding state is selected 2 2 4 TOUCH LOCKING Buttons can optionally be locked or u...

Page 13: ...locking and unlocking when receiving the configured scene value through the object General Scene receive Lock Scene Number 0 Disabled 0 1 64 scene number that locks the buttons Unlock Scene Number 0 D...

Page 14: ...TERIZATION After enabling the Customize Sounds in Configuration screen in Indoor Module see section 2 2 1 a new tab will be incorporated into the tree on the left Figure 6 Indoor Module Sounds Disable...

Page 15: ...ject for Alarm disabled enabled enables or disables the alarm function If enabled a specific object In Sounds Alarm will be included into the project topology Value 0 No Alarm 1 Alarm 0 Alarm 1 No Ala...

Page 16: ...f the indoor module it is equipped with a proximity sensor and an ambient luminosity sensor that will allow to adjust the backlight according to to different situations of presence or illumination Thi...

Page 17: ...ough the proximity sensor Please refer to the user manual Proximity and Luminosity Sensor available in the IDAC product section at the Zennio homepage www zennio com for detailed information about the...

Page 18: ...ut the functionality and configuration of the related parameters 2 3 3 BACKLIGHT The outdoor module has three LEDs each of which has a specific functionality Figure 8 Outdoor Module Backlight Access L...

Page 19: ...access LEDs will be on when trying to access the room States Configuration For each state of the room which will depend on the value of the objects Access Room State Status and Access Presence Occupan...

Page 20: ...Up Make Up Not Occupied Normal Normal Not Occupied Do Not Disturb Access Granted Do Not Disturb Access Granted Access Denied Occupied Make Up Make Up Occupied Normal Make Up Not Occupied Table 1 Stat...

Page 21: ...e has single button with doorbell functionality This button type can be configured as Switch Control whenever the user touches the button a binary value will be sent to the KNX bus This value is confi...

Page 22: ...ee section 2 3 3 If On is selected the LED Color parameter will be enabled allowing you to choose the desired color 2 3 5 TOUCH LOCKING Functionality analogous to that described for the Outdoor Module...

Page 23: ...al Module Sounds Disable Button Sounds disabled enabled enables or disables acoustic signals of actions derived from button presses and access attempts Enable Disable Button Sound Through a 1 bit Obje...

Page 24: ...IDAC https www zennio com Technical Support https support zennio com 24 2 3 7 AMBIENT LUMINOSITY SENSOR Functionality analogous to that described for the Outdoor Module see section 2 2 6...

Page 25: ...Do Not Disturb 9 1 Byte O C R T 1 xxx 0 1 Access Room State 0 Normal 1 Make Up Room 2 Do Not Disturb 10 1 Bit O C R T DPT_Bool 0 1 Access Room State Make Up Room Status 0 No Active 1 Active 11 1 Bit O...

Page 26: ...T_Switch 0 1 In Btnx Two Objects Short Press 0 1 1 Bit Generic Control 1 Byte I C W T DPT_Value_1_Ucount 0 255 In Btnx Two Objects Short Press 1 Byte Send Selected 1 Byte Value on Short Press 1 Byte I...

Page 27: ...tch 0 1 Out Btnx Two Objects Short Press 0 1 1 Bit Generic Control 1 Byte I C W T DPT_Value_1_Ucount 0 255 Out Btnx Room State 0 Normal 1 Make up room 2 Do not disturb 1 Byte I C W T DPT_SceneNumber 0...

Page 28: ...art 0 1 Out External Proximity Detection 1 Detection 63 1 Bit C T DPT_Start 0 1 Out Proximity Detection Send 1 when Proximity is Detected 64 1 Bit C T DPT_Bool 0 1 Out Luminosity 1 Bit 0 Over Threshol...

Page 29: ...n and send us your inquiries about Zennio devices https support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio...

Reviews: