15
blueBOX 150 1 FIX NN TPVC 1 1/2” NN NN 0000
TYPE
Zenit Italia s.r.l.
Via dell’Industria, 11
I-41018 S.Cesario s.P.
Modena - Italy
CODE
S.N.
YW
Kg
1017
21
CPR-13.506.317-13.506.318
EN 12050-1 EN 12050-2
Made in P.R.C.
blue
BOX
- Translation of the original instructions
Product type
Tank capacity (litres)
No. pumps envisaged
Configuration
FIX = fixed installation
DAC = installation with coupling
device
1. Type
2. Code
3. Weight (kg)
4. Serial number
5. Week and year of production
6. CE Marking
7.
Identification number of the notified laboratory for type testing
8. Manufacturer’s name and address
9.
Year in which the CE Marking was affixed for the first time
10. Declaration of performance reference no.
11. Reference standards
12. Production site
Presence of ball check valve on the
discharge pipe
NN = without check valve
VAP = with check valve
Discharge pipe material
TPVC = PVC
TX04 = Stainless steel AISI 304
TX16 = Stainless steel AISI 316
Discharge pipe diameter (in inches)
Presence of maximum level alarm float
NN = without alarm float
FA = with alarm float
Level sensor 4-20 mA
NN = Without sensor
FL = With sensor
Customer specific variant
0000 = No customer variant
XXXX = Customer variant
2. PRODUCT IDENTIFICATION
2.1 Description
The blueBOX lifting stations solve the problem of introducing wastewater or rainwater into the sewer system when the sewer system cannot be
reached by gravity and whenever it is necessary to grind the solids contained in the effluent before discharging it into the sewer.
The blueBOX lifting station consists of a polyethylene tank in which a submersible vortex impeller pump or grinding system (to be purchased
separately) must be installed. The blueBOX 500 model allows the use of 2 pumps.
The installation can be
fixed (FIX)
, using the connecting pipes (included), in which the pump is connected directly to the system, or with a
coupling device (DAC)
that allows the pump to be quickly separated from the system for cleaning and maintenance.
When the liquid in the tank reaches a level which sets the float switch or level sensor to the ON position, the pump starts, progressively emptying
the tank.
The pump stops when the liquid reaches the minimum level and switches the float switch or level sensor to the OFF position.
In the case of an installation with 2 pumps, the level control system must be programmed in such a way that the second pump starts to assist the
first pump in the event that the first pump is unable to empty the incoming effluent or if the first pump is blocked.
An emergency float, placed higher than the others, can be installed to signal an excessive liquid level in the tank.
In this case, an electrical control panel with a visual and/or audible alarm must be used.
Installation can be
indoors
(basements, cellars, sub-basements) or
outdoors
either
above
or
below
ground.
For outdoor use, it is mandatory to use pumps with a power supply cable with a minimum length of 10 m to ensure that the end of the cable cannot
come into contact with moisture or water, in accordance with EN 60335-2-41.
2.2 Intended use
The blueBOX can be installed for the collection and transfer of domestic and residential wastewater, rainwater and sewage.
It cannot be used in environments with the presence of dust, gases, acids, corrosive, flammable or explosive agents and with food-grade liquids.
The temperature of the installation site must be between 0°C (32°F) and +50°C (122°F).
The temperature of the contained liquid must not exceed 40°C (104°F) (up to 80°C/176°F for 3 min., the tank is therefore suitable for washing
machine and dishwasher drains).
caution!
Do not use the product for purposes other than those for which it was designed and indicated in the manual. Improper
use of the product may constitute a source of danger and invalidate the warranty.
2.3 Noise level
During operation, the lifting station has a sound pressure level of less than 70 dB(A).
2.4 Identification of the model
2.5 Nameplate
A nameplate is affixed to the tank cover indicating the main technical data relating to the product.
A silver adhesive label has been supplied together with this manual which shows the product characteristics indicated on the nameplate.
It is recommended that this label is affixed to a designated area inside the manual where it can be referred to in the event of any queries.
better together
EN
1
1
1
3
2
3
3
3
4
3
4
6
5
6
5
4
5
7
7
8
8
9
9
10
10
8
7
9
10
11
12
6