14
Any repairs to the motor pump must be carried out by the manufacturer or by specialist personnel. If this is not respected, the
guarantee will be invalidated and the machine may become unsafe.
5.2 CHECKING PARTS SUBJECT TO WEAR
Before inspection and maintenance operations carefully read and apply the safety procedures indicated in
paragraphs 1.2 and 1.3
During programmed maintenance or at any time in which the performance of the motor pump should be reduced or if
vibrations and noise should increase, the hydraulic parts subject to wear must be checked. Original spare parts only
should be used. If the hydraulic part should be partially or totally blocked it should be cleaned thoroughly with a jet of high
pressure water. If necessary dismantle the hydraulic part referring to the exploded view in fig. 2 - 2/a
To restore the hydraulic characteristics of the motor pump (GRN - APN - GRP - APP) use the appropriate hexagonal spanner on
the grub screws inside the inlet hole which regulate the distance between the impeller and the shimming plate, which must be
between 0.3 and 0.5 mm.
6. MINOR PROBLEMS: CAUSES AND SOLUTIONS
FAULTS
POSSIBLE CAUSE
SOLUTION
motor does not turn
no voltage
check the power supply line
automatic switch tripped
reset the switch and establish the cause
impeller jammed
establish the cause of the trouble and remove it
thermal protection cut in
resets automatically (not on -EX versions)
motor functions normally but no
water is pumped
check valve jammed
clean the valve and check its operation
blocked pipeline
identify the obstruction and remove it
pump has reduced flow rate
impeller, valve or pipelines obstructed
identify the obstruction and remove it
liquid level too low
turn the pump off immediately
incorrect supply voltage
match the voltage to the values indicated on the
data plate
wrong direction of rotation (three phase motor)
invert any two phases
thermal protector has cut in
impeller jammed
identify the cause of the trouble and remove it
temperature of liquid too high
contact your nearest zenit dealer
7. DISPOSING OF MOTOR PUMPS
In the event that is not considered economically viable to repair a worn or damaged motor pump, the motor pump and motor
must be disposed of in full compliance with local regulations.
To dispose of a motor pump proceed as follows:
- remove any oil in the chamber and dispose of in a specialised collection centre;
- separate the parts in plastic and rubber and dispose of in a specialised collection centre;
- arrange for the break-up of the metal parts.
Do not dispose of any motor pump component in the environment.
Summary of Contents for APE 200/2/G50H A0CM(T)-E
Page 2: ......
Page 69: ...67 Fig 2 a GRI 200 2 G50H A0CM T E...
Page 74: ...72...
Page 75: ......
Page 78: ......
Page 79: ...1 ITALIANO 2 ENGLISH 11 FRANCAIS 19 DEUTSCH 28 ESPANOL 37...
Page 134: ...56...
Page 135: ......
Page 138: ......
Page 165: ...29 1 4 3 1 1 1 1 2 KANONI 50 C GRT GRN GRP 1 3 DPI 2 3 EN GJL 250 EN GJL 250 UNI 1561 1563...
Page 167: ...31 4 2 1 1 4 2 2 4 3 8 8 1 2 1 3 1 4 4...
Page 169: ...33 6 EX zenit 7 8 8 1 3 4 8 2 3 6 3 U V W 6 U1 U2 V1 V2 W1 W2 5 6 8 3 8 4 S...
Page 217: ......
Page 218: ...Cod 272701002830000000 Rev 4 01 06 11 www zenit com...