89
MAN0585.P65
Issue 01 - 11/99
2987M5023
Two levels of instantaneous alarm (referred to as high and
very high) are available as an option on the explosive and
toxic channels.
Audible Alarm:
80dBA at 1 metre.
(approximately 90dBA at 1 foot).
7.1.6
Environmental Limits
Temperature:
-20° to +50°C (-4° to +122°F).
(0 to +40°C for CO
2
units).
7.1.7
Humidity
Continuous:
80% rh (non-condensing).
Intermittent:
99% rh (non-condensing).
Note: The use of the Minigas Mk5 in hazardous areas is limited to
+40°C. Storage of the Minigas Mk5 with its sensors fitted
should be limited to the temperature range 0°C to +25°C.
7.1.8
Intrinsic Safety Certification
Intrinsic safety approval (to Ex ias IIC T4/T3, or equivalent)
has been granted to the Minigas Mk5.
Authority
Certificate Number
Code
BASEEFA (UK)
Ex 93Y2379X
Ex ias IIC T4/T3
Ex 95C2440X
EEx ia IIC T4/T3
Ex 95Y8441X
Ex s IIC T4/T3
(T3 for NiMH, T4 for dry-cell)
SAA (Australia)
Aus Ex 1468X
Ex ias I/IIC T4
CAA (Canada)
Class 1, Groups A, B, C, D
UL (USA)
Class 1, Groups A, B, C, D
7. SPECIFICATIONS