At the end of the time set in the PR44 parameter, the message "Wait to cool" appears on the display. In this case, the auger is
turned off (auger LED OFF), the exchanger turns off when the threshold set in the PR15 parameter is reached, and the
ON/OFF LED blinks. (figure 11b)
Fig.11b
When the temperature of the smoke reaches the threshold set in the PR13 parameter, the stove goes into stand-by and the
message "Stop eco temp good" scrolls on the display. The auger is OFF (auger LED OFF), the exchanger is OFF (exchanger
LED OFF) and the smoke fan is also OFF. (figure 11c)
Fig.11c
If the room temperature drops below the set temperature (room setpoint) minus the threshold set in the PR43 parameter, the
stove re-starts.
c.14 Turning off the stove
To turn off the stove, simply press and hold the P3 button for a few seconds. The message "Final Clean") appears on the
display. (figure 12a) The motor of the auger stops (auger LED OFF), the smoke fan runs at the speed set in the PR08
parameter, and the ON/OFF LED blinks.
Fig.12°
The fan of the exchanger (exchanger LED ON) continues to run until the smoke temperature drops below the value set in the
PR15 parameter. After the period of time set in the PR39 parameter, the stove turns off and "OFF" appears on the display if
the temperature of the smoke is below the threshold set in the PR10 parameter. (figure 12b)
Fig.12b