102777-YIM-E-0206
Unitary Products Group
57
TABLE 29: COMPONENT STATIC RESISTANCE
1
2
COMPONENT COIL
LOSSES
CFM
6,000
8,000
10,000
12,000
14,000
16,000
18,000
Std. 25 Ton, Dry
-0.06
-0.08
-0.10
-0.13
-
-
-
Std. 25 Ton, Wet
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Std. 30 Ton, Dry
-0.045
-0.075
-0.112
-0.157
-0.207
-0.264
-0.326
Std. 30 Ton, Wet
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Hi Cap 30 Ton, Dry
-0.019
-0.035
-0.052
-0.073
-0.098
-0.124
-0.155
Hi Cap 30 Ton, Wet
0.042
0.069
0.103
0.142
0.186
0.236
0.290
Std. 40 Ton, Dry
-0.030
-0.051
-0.076
-0.106
-0.140
-0.177
-0.219
Std. 40 Ton, Wet
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Hi Cap 40 Ton, Dry
-0.020
-0.033
-0.050
-0.069
-0.092
-0.116
-0.144
Hi Cap 40 Ton, Wet
0.023
0.038
0.057
0.079
0.105
0.133
0.164
Filter Losses
2” TA or HI Eff.
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Baseline
Rigid 6”, 65%
0.048
0.080
0.119
0.165
0.217
0.274
0.338
Rigid 6”, 95%
0.189
0.308
0.448
0.609
0.790
0.988
1.205
IGV Losses
30 Ton
0.048
0.085
0.132
0.190
0.259
0.338
0.428
40 Ton
0.027
0.049
0.076
0.110
0.149
0.195
0.246
Gas Heat
233 MBH Heat
0.106
0.141
0.177
0.212
0.247
0.283
0.318
466 MBH Heat
0.212
0.283
0.353
0.424
0.495
0.566
0.636
699 MBH Heat
0.318
0.423
0.531
0.636
0.741
0.849
0.954
Electric Heat
0.050
0.100
0.150
0.310
0.430
0.530
0.680
Economizer*
0.063
0.104
0.153
0.210
0.276
0.349
0.429
Power Exhaust*
0.046
0.081
0.127
0.182
0.248
0.324
0.410
1.
Baseline losses based on system/cabinet effects, wet standard coil and 2-inch throwaway filters at 70°F, 0 degree elevation with
standard air.
2.
See Tables 56, 57, 65, and 66 for steam and hot water coil static resistance.
Summary of Contents for MILLENNIUM Y22
Page 47: ...102777 YIM E 0206 Unitary Products Group 47 FIGURE 20 ALTITUDE TEMPERATURE CONVERSION FACTOR ...
Page 50: ...102777 YIM E 0206 50 Unitary Products Group FIGURE 21 FAN PERFORMANCE 25 TON ...
Page 53: ...102777 YIM E 0206 Unitary Products Group 53 FIGURE 22 FAN PERFORMANCE 30 TON ...
Page 56: ...102777 YIM E 0206 56 Unitary Products Group FIGURE 23 FAN PERFORMANCE 40 TON ...
Page 126: ...102777 YIM E 0206 126 Unitary Products Group FIGURE 52 TYPICAL CONTROL WIRING ...
Page 127: ...102777 YIM E 0206 Unitary Products Group 127 FIGURE 53 LEGEND ...
Page 128: ...102777 YIM E 0206 128 Unitary Products Group FIGURE 54 TYPICAL 25 TON POWER WIRING ...
Page 129: ...102777 YIM E 0206 Unitary Products Group 129 FIGURE 55 TYPICAL 30 40 TON POWER WIRING ...
Page 130: ...102777 YIM E 0206 130 Unitary Products Group FIGURE 56 TYPICAL GAS HEAT WIRING ...
Page 134: ...102777 YIM E 0206 134 Unitary Products Group FIGURE 58 25 TON CHARGING CURVE ...
Page 139: ...102777 YIM E 0206 Unitary Products Group 139 ...