8.6.
Settings
Setting the parameter for YZ-TH by connecting the setting device.
Display Start Value START VALUE
Set contents
Selection Range
Default
Setting the display start value
.
The value to be as follows:
Upper limit value
≧
Cut value
≧
Start value
10~150
10
Speed Shift Value from Mid to High SWITCH VALUE
Set contents
Selection Range
Default
Set the value to switch from motor mid-speed to motor high speed.
The value must be, Switch value
≧
Start value
10~150
10
Cut Value
CUT VALUE
Set contents
Selection Range
Default
Set target value.
Set the value to be as follows:
Upper limit value
≧
Cut value
≧
Start value
.
20~150
20
Upper Limit Value MAX VALUE
Set contents
Selection Range
Default
Set Upper Limit Value. The value to be as follows:
Upper limit value
≧
Cut value
≧
Start value.
20~150
20
Motor Low Speed LOW SPEED
Set contents
Selection Range
Default
Set the motor low speed
1200~1500(rpm)
1200
Motor Middle Speed MIDDLE SPEED
Set contents
Selection Range
Default
Set the motor middle speed
1500~3000(rpm)
2000
Motor High Speed HIGH SPEED
Set contents
Selection Range
Default
Set the motor high speed
1500~4800(rpm) *YZ-TH600
2000~4800(rpm) *Others
3000