76-QD0460EN-01Y00-00
26
8.5.5.
Test Mode
Select TEST MODE by up & down key and press enter key to go to test mode screen.
By pressing [MAIN] key or [CAN] key, test mode finishes and it moves back to top MAIN MENU
screen.
The test mode can enable the tool to rotate the main shaft after pulling the throttle lever
as the usual rundown mode, and to tighten confirming the result after rundown judgement on
the test mode screen. It is used for parameter setting and output adjustment.
Test mode screen can display
50 pulses as the pulse data. To see more than 51 pulses, escape
from test mode once and confirm on the reference of the pulse data history screen explained on
8.5.4.
This is the operation by connecting with the setting device. Be careful of the cable
entanglement or the excessive load on the cable connecting port.
8.5.6. Maintenance
Select MAINTENANCE by up & down key and press enter key to go to maintenance screen.
On the MAINTENANCE screen, select each item by up & down key and press enter key to
conduct each function.
By pressing [MAIN] key or [CAN] key, it moves back to top MAIN MENU screen.
SETTING INIT
:
Initializing the setting parameter to the default value
。
DATA CLEAR
:
Deleting all stored rundown data including the rundown results and
pulse data.
1. PARAMETER SETTING
2. RUNDOWN DATA
3. PULSE DATA
4. TEST MODE
5. MAINTENANCE
MAIN MENU (600 V1.00)
TEST MODE
03A- 20- 6- Aok
6- 12- 15– 19– 20- 21
MAIN
ENT
CAN
1. PARAMETER SETTING
2. RUNDOWN DATA
3. PULSE DATA
4. TEST MODE
5. MAINTENANCE
MAIN MENU (600 V1.00)
MANITENANCE
1. SETTING INIT
2. DATA CLEAR
MAIN
ENT
CAN