76-QD0460EN-01Y00-00
24
8.5.3. Reference of
rundown result history
Select RUNDOWN DATA by up & down key and press enter key to go to the RUNDOWN DATA
screen. If the rundown result is more than one page, press [NEXT] key to move to the next page
and press [PREV]to move back to the previous page.
The latest 50 rundown data is stored.
By pressing [MAIN] key or [CAN] key, it moves back to top MAIN MENU screen.
Rundown result screen
Items
Contents
Rundown Sequence
Rundown sequence no.
(1~99)
Total Judgement
Rundown judgement result, OK or NG
A : Tightening OK
N : Tightening NG
Output Value
Output value at rundown judgement
Pulse number
Pulse number at rundown judgement
Rundown result details
Rundown judgement result details
Aok : OK
Udr : Under Value
Ovr : Over Value
N55 : Under Pulse
N57 : Over Pulse
Slw :
Pulses exceed preset slow error pulses
(70 fixed ) including those less than
display start value
RUNDOWN DATA
RES VAL PLS INF
01. 03A– 20- 6 -Aok
02. 02A- 32– 12 -Aok
03. 01N- 40– 18 –Ovr
MAIN NEXT PREV
1. PARAM SETTING
2. RUNDOWN DATA
3. PULSE DATA
4. TEST MODE
5. MAINTENANCE
MAIN MENU (600 V1.00)
CAN