4-10
<Toc>
<4. Troubleshooting and Maintenance>
IM 05D01C12-41E
4th Edition: May 31, 2006-00
4.
Hold the bezel and pull it along with the internal unit out of the housing.
(Note) Be careful not to damage the RJC sensor.
5.
The location and number of the relays differ depending on the model code of the UT450/
UT420.
Confirm the location of the control output relay to be replaced before pulling out the
relay.
Relay (UT450-0
䊐
or UT420-0
䊐
)
Two relays for direct and reverse action (UT450-1
䊐
)
Upper
Lower
6.
Pull out the relay to be replaced.
The control output relays are easy to remove and mount, since they are connected via a
socket onto the print boards.
Insert the new relay in the socket. Use the following relay.
Manufacturer
OMRON
Model
G6B-2114P-FD-US-P6B
Power supply
12 V DC
Summary of Contents for NEW GREEN SERIES