A4-4
IM 34M06H63-01E
2nd Edition : Jul.16, 2015-00
Table A4.1 Input Type Selection (2/2) (SW1-1 = ON)
Input Type
Instrument
Default Range
*1
Input Type
Selector Switch
*2
Software
Setting
Input Range
Default
Preset Range
SW5
SW1-4 SW1-3
IN
*3
RL
RH
DEC.P
RL
RH
Software setting
*4
0
OFF
X
T
h
e
rm
o
c
o
u
p
le
K
-328.0 to 2498.0°F
1
OFF
OFF
1
($01)
-3280
24980
1
-4540
24980
ON
33
($21)
-328
2498
0
-454
2498
-328.0 to 1832.0°F
2
OFF
2
($02)
-3280
18320
1
-4540
24980
ON
34
($22)
-328
1832
0
-454
2498
-328.0 to 932.0°F
3
OFF
3
($03)
-3280
9320
1
-3280
9320
ON
35
($23)
-328
932
0
-328
932
J
-328.0 to 2192.0°F
4
OFF
4
($04)
-3280
21920
1
-3280
21920
ON
36
($24)
-328
2192
0
-328
2192
-328.0 to 932.0°F
5
OFF
5
($05)
-3280
9320
1
-3280
9320
ON
37
($25)
-328
932
0
-328
932
T
-454.0 to 752.0°F
6
OFF
6
($06)
-4540
7520
1
-4540
7520
ON
38
($26)
-454
752
0
-454
752
B
32 to 2912 °F
7
OFF
7
($07)
32
2912
0
32
3272
ON
39
($27)
32
2912
0
32
3272
S
32 to 2912 °F
8
OFF
8
($08)
32
2912
0
32
3092
ON
40
($28)
32
2912
0
32
3092
R
32 to 2912 °F
9
OFF
9
($09)
32
2912
0
32
3092
ON
41
($29)
32
2912
0
32
3092
N
-328.0 to 2372.0°F
A
OFF
10
($0A)
-3280
23720
1
-3280
23720
ON
42
($2A)
-328
2372
0
-328
2372
E
-454.0 to 1832.0°F
B
OFF
11
($0B)
-4540
18320
1
-4540
18320
ON
43
($2B)
-454
1832
0
-454
1832
L
-328.0 to 1652.0°F
C
OFF
12
($0C)
-3280
16520
1
-3280
16520
ON
44
($2C)
-328
1652
0
-328
1652
U
-328.0 to 752.0°F
D
OFF
13
($0D)
-3280
7520
1
-3280
7520
ON
45
($2D)
-328
752
0
-328
752
W
32 to 2912 °F
E
OFF
14
($0E)
32
2912
0
32
4172
ON
46
($2E)
32
2912
0
32
4172
Platinel 2
32.0 to 2534.0°F
F
OFF
15
($0F)
320
25340
1
320
25340
ON
47
($2F)
32
2534
0
32
2534
R
T
D
JPt100
-328.0 to 932.0°F
0
ON
OFF
16
($10)
-3280
9320
1
-3280
9320
ON
48
($30)
-328
932
0
-328
932
-328.0 to 392.0°F
1
OFF
17
($11)
-3280
3920
1
-3280
3920
ON
49
($31)
-328
392
0
-328
392
32.0 to 572.0°F
2
OFF
18
($12)
320
5720
1
320
5720
ON
50
($32)
32
572
0
32
572
32.0 to 302.0°F
3
OFF
19
($13)
320
3020
1
320
3020
ON
51
($33)
32
302
0
32
302
Pt100
-328.0 to 1562.0°F
4
OFF
20
($14)
-3280
15620
1
-3280
15620
ON
52
($34)
-328
1562
0
-328
1562
-328.0 to 932.0°F
5
OFF
21
($15)
-3280
9320
1
-3280
9320
ON
53
($35)
-328
932
0
-328
932
-328.0 to 392.0°F
6
OFF
22
($16)
-3280
3920
1
-3280
3920
ON
54
($36)
-328
392
0
-328
392
32.0 to 572.0°F
7
OFF
23
($17)
320
5720
1
320
5720
ON
55
($37)
32
572
0
32
572
32.0 to 302.0°F
8
OFF
24
($18)
320
3020
1
320
3020
ON
56
($38)
32
302
0
32
302
D
C
v
o
lt
a
g
e
0-10mV
0.00 to 10.00 mV
9
ON
X
25
($19)
0
1000
2
0
1000
0-100mV
0.0 to 100.0 mV
A
26
($1A)
0
1000
1
0
1000
0-1V
0.000 to 1.000 V
B
27
($1B)
0
1000
3
0
1000
0-5V
0.000 to 5.000 V
D
29
($1D)
0
5000
3
0
5000
1-5V
1.000 to 5.000 V
E
30
($1E)
1000
5000
3
1000
5000
0-10V
0.00 to10.00 V
F
31
($1F)
0
1000
2
0
1000
*1: For thermocouples K, B, S, R, and W, the upper and lower input range limits may exceed the default values.
*2:
Data stored in the internal memory is initialized to the hardware switch values when power is turned on. An
‘X’ symbol in the SW1-3
column indicates that the switch setting is ignored.
*3:
“Software Setting” refers to values stored in data register IN. Any value not listed here is ignored.
*4:
This is the factory setting. When
‘set by software’ is selected, the initial value of data register IN is 1 i.e. ‘software setting’=1.
Summary of Contents for FA-M3 VITESSE F3CX04-0N
Page 2: ...Blank Page...
Page 16: ...Blank Page...
Page 18: ...Blank Page...
Page 32: ...Blank Page...
Page 44: ...Blank Page...
Page 68: ...Blank Page...
Page 80: ...Blank Page...
Page 82: ...Blank Page...
Page 90: ...Blank Page...
Page 110: ...Blank Page...
Page 118: ...Blank Page...
Page 126: ...Blank Page...
Page 128: ...Blank Page...
Page 132: ...Blank Page...
Page 142: ...Blank Page...
Page 144: ...Blank Page...