3. HANDLING CAUTIONS
(6) Name Plate
Name plate
Tag plate for flameproof type
Tag plate for intrinsically safe type
F0311E.EPS
D
D
AFTER DE-ENERGIZING, DELAY 5 MINUTES
BEFORE OPENING.
WHEN THE AMBIENT TEMP.
!
65
°
C,
USE THE HEAT-RESISTING CABLES
!
90
°
C
No. KEMA 03ATEX2570
EEx d IIC T6...T4 IP66 andIP67
TEMP. CLASS T6 T5 T4
MAX PROCESS TEMP.(Tp.) 85 100 120
°
C
Tamb. -50 to 70 80 75
°
C
T80
°
C(Tamb.:40
°
C, Tp.:80
°
C),T100
°
C(Tamb.:60
°
C, Tp.:100
°
C),
T120
°
C(Tamb.:80
°
C, Tp.:120
°
C) Min.Tamb.:-40
°
C(for DUST)
No. KEMA 06ATEX0037 X
EEx ia IIC T4
IP66 and IP67
Tamb. -50 to 60
°
C MIN. Tamb.:-40
°
C(for DUST)
MAX. PROCESS TEMP.(Tp.) 120
°
C
T85
°
C(Tp.:80
°
C), T100
°
C(Tp.:100
°
C), T120
°
C(Tp.:120
°
C)
Supply/Pulse circuit
Ui=30V, Ii=200mA, Pi=0.9W, Ci=10nF, Li=0
Sensor circuit
Uo=30V, Io=95.4mA, Po=0.468W, Ci=11nF, Lo=3.9mH
WARNING
MODEL: Specified model code.
STYLE: Style code
SUFFIX: Specified suffix code.
SUPPLY: Supply voltage.
OUTPUT: Output signal.
MWP: Maximum working pressure.
CAL RNG: Specified calibration range.
NO.: Serial number and year of production
*1
.
TOKYO 180-8750 JAPAN:
The manufacturer name and the ad-
dress
*2
.
*1: The first ditital in the final three numbers of the
serial number appearing after “NO.” on the nameplate
indicates the year of production. The following is an
example of a serial number for a product that was
produced in 2004:
*2: “180-8750” is a zip code which represents the
following address.
2-9-32 Nakacho, Musashino-shi, Tokyo Japan
3.10 EMC Conformity Standards
EN61326 Class A
AS/NZS CISPR 11
CAUTION
To meet EMC regulations, Yokogawa recom-
mends that customers run signal wiring through
metal conduits or use shielded twisted-pair
cabling when installing EJX series transmitters in
a plant.
3.11 Pressure Equipment
Directive (PED)
(1) General
• EJX series pressure transmitters are categorized as
pressure accessories under the vessel section of
directive 97/23/EC, which corresponds to Article 3,
Paragraph 3 of PED, denoted as Sound Engineering
Practice (SEP).
• EJX910A-
M and EJX910A-
H can be used
above 200 bar and therefore considered as a part of
a pressure retaining vessel where category III,
Module H applies. These models with option code /
PE3 conform to that category.
(2) Technical Data
• Models without /PE3
Article 3, Paragraph 3 of PED, denoted as Sound
Engineering Practice (SEP).
• Models with /PE3
Module : H
Type of Equipment :Pressure Accessory - Vessel
Type of fluid : Liquid and Gas
Group of fluid : 1 and 2
Model
EJX910A
EJX910A
with code /PE3
Category
*2
Article 3, Paragraph 3
(SEP)
III
PS.V
(bar.L)
1.6
2.5
2.5
V(L)
0.01
0.01
0.01
PS
(bar)
*1
160
250
250
*1: PS is maximum allowable pressure for vessel itself.
*2: Referred to Table 1 covered by ANNEX II of EC Directive
on Pressure Equipment Directive 97/23/EC
T0302E.EPS
Capsule
code
L
M, H
M, H
(3) Operation
CAUTION
• The temperature and pressure of fluid should
be maintained at levels that are consistent with
normal operating conditions.
• The ambient temperature should be maintained
at a level that is consistent with normal operat-
ing conditions.
• Please take care to prevent water hammer and
the like from inducing excessive pressures in
pipes and valves. If phenomena are likely,
install a safety valve or take some other
appropriate measure to prevent pressure from
exceeding PS.
• Take appropriate measures at the device or
system level to protect transmitters if they are
to be operated near an external heat source.