APPENDIX 2. INTEGRATOR (IT) BLOCK
A2.5.2 Determining the Output Value
The value of OUT.Value is determined as follows:
For counting up
OUT = integration start value (0) + Total
For counting down
OUT = integration start value (TOTAL_SP) _ Total
Total: Total of integrated values. This value is retained even if INTEG_TYPE is changed during integration
(in AUTO).
If OUT is rewritten in the MAN mode, integration starts with the value rewritten in MAN mode after the mode was
returned to AUTO.
The values in OUT_TRIP and OUT_PTRIP are determined according to the correlation between OUT and
TOTAL_SP/PRE_TRIP.
OUT_TRIP(#14):0
OUT_PTRIP(#15):0
OUT_TRIP(#14):1
OUT_PTRIP(#15):1
Counting up starting from 0
• For counting up
PRE_TRIP(#31)
OUT_TRIP(#14):0
OUT_PTRIP(#15):0
OUT_TRIP(#14):0
OUT_PTRIP(#15):1
OUT_TRIP(#14):1
OUT_PTRIP(#15):1
• For counting down
Counting down starting from TOTAL_SP
PRE_TRIP(#31)
0
0
TOTAL_SP(#7)
TOTAL_SP(#7)
FA0205.EPS
OUT_TRIP(#14):0
OUT_PTRIP(#15):1