IM 01C25R03-01E
A-8
APPENDIX 1. SIGNAL CHARACTERIZER (SC) BLOCK
To enable backward control (which inverts the X and
Y axes), the line-segment function must be set so that
the elements of the curve increase in a monotone
manner.(As shown in Figure A1.11) If they do not
increase in a monotone manner, the mode changes to
O/S, disabling calculation.
CURVE_X CURVE_Y
No.
5
5
1
10
10
2
15
11
3
20
20
4
25
25
5
30
26
6
35
30
7
40
40
8
45
45
9
50
50
10
51
51
11
52
54
12
53
59
13
54
66
14
55
75
15
65
80
16
75
81
17
80
85
18
85
86
19
90
90
20
95
95
21
TA0105.EPS
100
90
80
70
60
50
40
30
20
10
0
10
20
30
40
50
60
70
80
90
100
FA0111.EPS
Line-segment function
CURVE_Y
CURVE_X
X_RANGE = 100, 0, %, 0x00
Y_RANGE = 100, 0, %, 0x00
Figure A1.11 Setting Example of a Line-segment Function