Effective Date: May 29, 2018 | 02-4001-09
Page-27
YES 45 FS/FI Storefront System
3/16”
3/16”
1/2”
E2-0052
E2-0052
E2-0064
E9-1040
E2-0052
E2-0052
E2-0052
E9-1040
E9-1039
E2-0053
E2-0053
E2-0053
E9-1040
E9-1039
—
E2-0053
E2-0053
E2-0064
E2-0052
E9-1040
E9-1039
—
E2-0064
E2-0064
E2-0064
E2-0052
E2-0052
E2-0052
E2-0052
E2-0052
E2-0053
E2-0053
E2-0053
E2-0064
E2-0052
Exterior
Exterior
Adaptor
Glass
Thickness
Glass
Thickness
Glazing Table - YES 45 FS
Horizontal
Vertical
Glazing Table - YES 45 FI
Interior
Interior
1/4”
1/4”
5/8”
5/16”
5/16”
3/4”
3/8”
3/8”
7/8”
1”
Seal Corners
Of Glazing Adaptors
Apply and
Tool Sealant
FRAME INSTALLATION
STEP 17 (Optional)
INSTALL GLAZING ADAPTORS
Glazing adaptors, E9-1039 and E9-1040, allow
for glazing infills other than the standard 1/4”
or 1”. Please refer to the glazing tables on the
right for possible adaptor/gasket combinations.
-Snap glazing adaptors into the interior gasket
reglets of the verticals.
-Snap glazing adaptors into the interior gasket
reglets of the horizontals.
-Apply and tool sealant to the joint between
vertical and horizontal glazing adaptors.
See
Detail 32.
Detail 32
STEP 16
APPLY INTERNAL SEALANT
-Apply a generous amount of sealant to the
vertical intersection of the horizontal and
vertical members.
-Tool all of the sealant to ensure a water-
tight joint.
-Make sure all exposed screw heads are sealed.
See
Detail 31.
Detail 31
YES 45 FI Shown
Other Systems Similar
Summary of Contents for YES 45 FS
Page 2: ......
Page 35: ......