02-4001-09 | Effective Date: May 29, 2018
Page-20
YES 45 FS/FI Storefront System
FRAME INSTALLATION
E2-0070
12”
3/8”
Seal All
Screw Heads
Sill
Flashing
Sealant
3/8”
12”
STEP 12
INSTALL SILL FLASHING AT CORNERS
-Cut two 12" long pieces of sill flashing and miter (45° for 90°corners and 67.5° for 135° corners).
-Align the two pieces at the corner condition with the mitered ends pushed together tight and
anchor the sill flashing as called out on shop drawings.
-Apply and tool sealant to the mitered joint and anchor heads.
See
Detail 21
.
-Continue installing the rest of the sill flashing providing a 3/8" expansion joint at splices as shown
in
Step 10
on
Page 18
.
Detail 21