4
-30
A
Run command source selection status (ON: Run command from Operator)
Yes
Yes
Yes
5-47
B
Overtorque/undertorque detection 1 NO (NO contact, ON: Overtorque/undertorque
detection)
Yes
Yes
Yes
5-47
C
Loss of frequency reference (Effective when 1 is set for L4-05)
Yes
Yes
Yes
5-36
D
Braking resistor fault (ON: Resistor overheat or braking transistor fault)
Yes
Yes
Yes
5-37
E
Fault (ON: Digital Operator/Monitor communications error or fault other than
CPF00 and CPF01 has occurred.)
Yes
Yes
Yes
5-47
F
Not used. (Set when the terminal is not used.)
Yes
Yes
Yes
-
10
Minor fault (ON: Alarm displayed)
Yes
Yes
Yes
5-47
11
Fault reset command active
Yes
Yes
Yes
5-48
12
Timer function output
Yes
Yes
Yes
-
13
f
ref
/f
set
agree 2 (detection width L4-04 is used)
Yes
Yes
Yes
5-24
14
f
ref
/f
set
agree 2 (ON: Output frequency = L4-03, with detection width L4-04 is used,
and during frequency agree)
Yes
Yes
Yes
5-24
15
Frequency detection 3 (ON: Output frequency
≤
-L4-03, detection width L4-04 is
used)
Yes
Yes
Yes
5-24
16
Frequency detection 4 (ON: Output frequency
≥
-L4-03, detection width L4-04 is
used)
Yes
Yes
Yes
5-24
17
Overtorque/undertorque detection 1 NC (NC Contact, OFF: Torque detection)
Yes
Yes
Yes
5-47
18
Overtorque/undertorque detection 2 NO (NO Contact, ON: Torque detection)
Yes
Yes
Yes
5-47
19
Overtorque/undertorque detection 2 NC (NC Contact, OFF: Torque detection)
Yes
Yes
Yes
5-47
1A
During reverse run (ON: During reverse run)
Yes
Yes
Yes
5-48
1B
During baseblock 2 (OFF: During baseblock)
Yes
Yes
Yes
5-48
1D
During regenerative operation
No
No
Yes
5-48
1E
Restart enabled (ON: Restart enabled)
Yes
Yes
Yes
-
1F
Motor overload (OL1, including OH3) pre-alarm (ON: 90% or more of the detection
level)
Yes
Yes
Yes
5-39
20
Inverter overheat (OH) pre-alarm (ON: Temperature exceeds L8-02 setting)
Yes
Yes
Yes
5-40
30
During torque limit (current limit) (ON: During torque limit)
No
Yes
Yes
5-30
31
During speed limit
No
No
Yes
-
33
Zero-servo end (ON: Zero-Servo completed)
No
No
Yes
-
37
During run 2 (ON: Frequency output, OFF: Base block, DC injection braking, initial
excitation, operation stop)
Yes
Yes
Yes
5-47
38
During cooling fan operation
Yes
Yes
Yes
5-48
40
Brake Release Command
Yes
Yes
Yes
-
41
Output Contactor Close Command
Yes
Yes
Yes
-
42
Speed detection at deceleration
Yes
Yes
Yes
-
43
Not Zero Speed
Yes
Yes
Yes
-
Set-
ting
Value
Function
Control Methods
Page
V/f
Open
loop
Vector
Closed
Loop
Vector
http://nicontrols.com
Summary of Contents for Varispeed L7
Page 3: ...http nicontrols com...
Page 55: ...2 30 http nicontrols com...
Page 129: ...4 62 http nicontrols com...
Page 197: ...5 68 http nicontrols com...
Page 219: ...6 22 http nicontrols com...
Page 243: ...9 14 http nicontrols com...